11. Appendix
MX-FR Series Modular Matrix Frames – User's Manual
173
Applied CPU2 firmware: v3.5.7b8 | LDC software: v2.5.17b2
Ethernet Port
Connector type .............................................................................
Neutrik etherCON / RJ45 female connector
Ethernet data rate ..........................................................................
10/100Base-T, full duplex with autodetect
Power over Ethernet (PoE) ..........................................................................................................Not supported
Ethernet protocol .....................................................................................................
TCP/IP, HTTP, TFTP, Telnet
Alarm Output
Connector type ......................................................................................................SMPTE 269M standard BNC
11.2. Applied Ports (Network Settings)
The following ports are necessary to pass via a network switch/firewall for a proper working between the
device and the softwares:
Purpose/function
Affected
software
Protocol
Port nr.
Device Discovery
LDC
UDP
224.0.0.251:5353
Remote IP
LDC
UDP
230.76.87.82:37421
LW2 protocol
-
TCP
10001
HTTP port
-
TCP
80
11.3.
Factory Default Settings
Network Settings
IP address
192.168.254.254
Subnet mask
255.255.0.0
Static gateway
0.0.0.0
DHCP
Disabled
LW2 Port number
10001
HTTP Port number
80
Control protocol
LW2
Video Port Settings
Crosspoint state
I1 input port on all output ports
Input/Output ports
Unmuted, Unlocked
Emulated EDID (input ports)
F49 – Universal HDMI EDID
EDID memory
Empty (User and Dynamic EDIDs)
Crosspoint presets
All outputs to I1
Preset names
Preset1, Preset2,...
Port names
Input1, Input2...; Output1, Output2...
RS-232 Settings
Baud rate
57600
Databits
8
Parity
No
Stopbits
1
Control protocol
LW2