MODEX-OPTS, MODEX-OPTM
User’s Manual
Section 5. Front panel operations
Page 33 / 113
5.4.4. MODEX-IF-AUD
Settings
Application mode: Basic working mode can be set; for details about application
modes see section
on page
-
(0) Analog
Emb. & Ret. Aux (default): Analog audio to Main audio
Group, S/PDIF to S/PDIF Audio Group (see section
on page
-
(1) Analog
Forw. & Ret., S/: Analog audio to S/PDIF Audio Group,
-
(2) S/PDIF
Emb., Analog not: S/PDIF audio in to Main Audio Group,
Analog audio disabled (see section
on page
Changes are stored automatically without pressing the enter
button.
Analog in: Certain parameters of the input signal can be adjusted as follows:
-
Gain:
from 0 dB to +24 dB, step 3 dB (default is 0 dB)
-
Volume:
from 0 dB to -63 dB, step 0.5 dB (default is 0 dB)
-
Balance:
from 0 to 100%, step 1% (default is 50%=center)
Use the up
▲ and down ▼ buttons to change values. Changes are stored
automatically without pressing the enter
button.
Analog out: Certain parameters of the output signal can be adjusted as follows:
-
Volume:
from 0 dB to -52 dB (step 0.5 dB), from -54 dB to -66 dB (step
2 dB); -69 dB; -72 dB; -78 dB (default is 0 dB)
-
Balance:
from 0 to 100%, step 1% (default is 50%=center)
Use the up
▲ and down ▼ buttons to change values. Changes are stored
automatically without pressing the enter
button.
5.4.5. MODEX-IF-RS232-IR
Settings
RS232:
-
Baud rate: 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 / 128000 /
153600 / 230400 / 256000
-
Data bits: 5 / 6 / 7 / 8 / 9
-
Stop bits: 1 / 1.5 / 2
-
Parity: None / Odd / Even / Mark / Space
IR Input
-
Carrier frequency: from 30.000 to 200.000 Hz, step 500 Hz (default is
38.000 Hz)
IR Output
-
Carrier frequency: from 30.000 to 200.000 Hz, step 500 Hz (default is
38.000 Hz)
Use navigation buttons to change values and press the enter