5. Software Control – Lightware Device Controller
MMX8x4-HT series – User's Manual
61
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
Display
This section gives a feedback about the basic information of the connected sink device.
▪
Display name / Preferred resolution / HDMI capable / HDCP capable /HDCP repeater / Deep Color
Support / Deep Color YUV support
Frame Detector
See more details about the Frame Detector in the
CEC
See more details about the CEC feature in
section.
Other
for the selected port.
6.6.
Diagnostic Tools
6.6.1.
Cable Diagnostics
The cable diagnostics is a useful tool to determine any cable related issues in case of TPS connection.
The estimated cable length and the quality of the link are measured periodically and the diagnostic window
shows the values in real-time. If the green bars hit the first line in the middle they turn into red. It means
the number of the errors – during the extension – is higher than recommended. The link might be alive but
recovering of the received data is not guaranteed.
INFO: Each bar represents a differential line in the CATx cable. The inappropriate termination of the cable
usually causes high error rates. Check the cable terminations or change the cable.
#diagnostic
Cable Diagnostic Window
Reference Values
Value
Explanation
10
-10
-10
-9
Excellent image quality
10
-8
Minor error, not recognizable by eyes
10
-7
Sometimes recognizable flash on a special test pattern
10
-6
Small noise can be seen
10
-5
Easy to recognize image error
10
-4
Bad image quality
Above displayed “Video BER < 10
-10
” value means that on average there is 1 bad pixel after 10
10
pixels, which
means the number of the bit errors is about 1 pixel in every 80 seconds.