7.LW3Programmers’Reference
HDMI-TPS-RX110AY series – User's Manual
108
Appliedfirmwarepackage:v1.5.0b3 | LDCsoftware:v2.5.9b2
7.17. RS-232 Port Configuration
INFO:
Serial (local and link) port numbering can be found in the
section.
7.17.1.
Protocol Setting
Command and Response
#rs232 #rs-232 #serial
ç
SET·/MEDIA/UART/
<port>
.ControlProtocol=
<protocol>
æ
pw·/MEDIA/UART/
<port>
.ControlProtocol=
<protocol>
Parameters
Identifier
Parameter description
Value
Parameter value
<protocol>
Control protocol which is
applied on the selected
serial port
0
LW2protocol
1
LW3protocol
Example
ç
SET/MEDIA/UART/P1.ControlProtocol=1
æ
pw/MEDIA/UART/P1.ControlProtocol=1
7.17.2.
BAUD Rate Setting
Command and Response
ç
SET·/MEDIA/UART/
<port>
.Baudrate=
<baudrate>
æ
pw·/MEDIA/UART/
<port>
.Baudrate=
<baudrate>
Parameters
Identifier
Parameter description
Value
Parameter value
<baudrate>
BAUD rate value
0
4800
1
7200
2
9600
3
14400
4
19200
5
38400
6
57600
7
115200
Example
ç
SET/MEDIA/UART/P1.Baudrate=2
æ
pw/MEDIA/UART/P1.Baudrate=2
7.17.3.
Databits Setting
Command and Response
ç
SET·/MEDIA/UART/
<port>
.DataBits=
<databits>
æ
pw·/MEDIA/UART/
<port>
.DataBits=
<databits>
Parameters
Identifier
Parameter description
Value
Parameter value
<databits>
Databits value
8
8
9
9
Example
ç
SET/MEDIA/UART/P1.DataBits=8
æ
pw/MEDIA/UART/P1.DataBits=8
7.17.4.
Stopbits Setting
Command and Response
ç
SET·/MEDIA/UART/
<port>
.StopBits=
<stopbits>
æ
pw·/MEDIA/UART/
<port>
.StopBits=
<stopbits>
Parameters
Identifier
Parameter description
Value
Parameter value
<stopbits>
Stopbits value
0
1
1
1,5
2
2
Example
ç
SET/MEDIA/UART/P1.StopBits=0
æ