5. Software Control - Lightware Device Controller
UMX-TPS-TX100 series – User's Manual
66
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
Configuration Example for the Message Recognizer
The detailed description below shows how to configure the message recognizer in
When the UMX-TPS-TX140-Plus has an active video signal, the transmitter login the VC codec automatically.
The signal presence triggers a bi-directional communication with the VC codec via RS-232:
Step 1.
Turn on the recognizer: Enable it on the P1 serial port.
Step 2.
Set the delimiter (in hex format). In this case, the
delimiter character is '
:
', which is '
3a
' in hex format.
When the delimiter string is detected in the incoming
serial data, the serial message is stored in string (in Rx
and ActiveRx property), hex (in RxHex and ActiveHex
property) and hash (in Hash and ActiveHash property) format. These stored content can be set as a
condition in the event manager.
INFO:
The stored content is the incoming data which arrives
before
the delimiter or
between
the two
delimiters.
Step 3.
Set the Active timeout 100. This property is responsible for erasing the temporary storage (ActiveRx,
ActiveRxHex, ActiveHash) after the elapsing time. In the below example, it can be seen how does the
recognizer properties change during the communication:
ç
UMX-TPS-TX140-Plus:
PING
Rx
RxHex
Hash
ActiveRx
ActiveRxHex
ActiveHash
æ
VC codec:
Login:
Rx
RxHex
Hash
ActiveRx
ActiveRxHex
ActiveHash
Login:
4C6F67696E3A
2D8A5E38
Login:
4C6F67696E3A
2D8A5E38
ç
UMX-TPS-TX140-Plus:
Admin
Active timeout is elapsed, so the values of the Active- prefixed properties are deleted.
Rx
RxHex
Hash
ActiveRx
ActiveRxHex
ActiveHash
Login:
4C6F67696E3A
2D8A5E38
æ
VC codec:
Password:
Rx
RxHex
Hash
ActiveRx
ActiveRxHex
ActiveHash
Password:
50617373776F72643A 79059B26
Password:
50617373776F72643A
79059B26
ç
UMX-TPS-TX140-Plus:
Admin
Active timeout is elapsed, so the values of the Active- prefixed properties are deleted.
Rx
RxHex
Hash
ActiveRx
ActiveRxHex
ActiveHash
Password:
50617373776F72643A 79059B26
... Password :
Login name :
...
Delimiter (hex format: 3A)
Stored string
5.9.3.
GPIO Tab
GPIO Tab in the Control Menu
The GPIO port has 7 pins, which operate at TTL digital signal levels and can be controlled by LDC or protocol
commands. Select a GPIO pin and under the Port settings section; the settings (pin direction and input level)
are displayed on the port tiles as well:
#gpio
1
GPIO pin name
4
High level indicator *
2
GPIO port icon
5
Pin direction:
Input
: down arrow
Output
: up arrow
3
Low level indicator
6
GPIO port number
* Highlighted with black means the current setting.
INFO:
Output level can be set only in case of setting the pin direction to Output. In case of input direction
the output level setting and the Toggle button is not available.
For more details about GPIO interface see the
GP1
P1
1
2
3
5
4
6