6.LW2Programmers'Reference
HDMI-TPS-RX110AY series – User's Manual
61
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3
6.6.3.
Link RS-232 Parameters Settings
The parameters of link RS -232 (TPS) port can be set as follows.
Command and Response
ȩ
{RS232_LINK_FORMAT=
<BaudRate>
;
<DataBit>
;
<Parity>
;
<StopBit>
}
Ȩ
(RS232_LINK_FORMAT=
<BaudRate>
;
<DataBit>
;
<Parity>
;
<StopBit>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<BaudRate>
Baud rate
X
No change
4800
4800
7200
7200
9600
9600
14400
14400
19200
19200
38400
38400
57600
57600
115200
115200
<DataBit>
Data bit
X
No change
8
8
9
9
<Parity>
Parity
X
No change
N
None
E
Even
O
Odd
<StopBit>
Stop Bit
X
No change
1
1
1,5
1,5
2
2
Example
ȩ
{rs232_link_format=9600;8;O;X}
Ȩ
(RS232_LINK_FORMAT=9600;8;O;X)
Explanation
LinkRS-232portissetasthefollowing:thebaudrateto9600,databitto8,paritytoodd,andstopbitisnot
changed, remained 1.
INFO:
ThecurrentlinkRS-232parameterscanbequeriedbythe{RS232_LINK_FORMAT=?}command.
6.6.4.
Local RS-232 Control Protocol Port Setting
The control protocol of local RS -232 port can be set as follows.
Command and Response
ȩ
{RS232_LOCAL_PROT=
<protocol>
}
Ȩ
(RS232_LOCAL_PROT=
<protocol>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<protocol>
RS-232 control protocol
LW2
LW2controlprotocol
LW3
LW3controlprotocol
Example
ȩ
{rs232_local_prot=lw2}
Ȩ
(RS232_LOCAL_PROT=LW2)
INFO:
ThecurrentlocalRS-232parameterscanbequeriedbythe{RS232_LOCAL_PROT=?}command.
6.6.5.
Link RS-232 Control Protocol Port Setting
The control protocol of link RS -232 (TPS) port can be set as follows.
Command and Response
ȩ
{RS232_LINK_PROT=
<protocol>
}
Ȩ
(RS232_LINK_PROT=
<protocol>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<protocol>
RS-232 control protocol
LW2
LW2controlprotocol
LW3
LW3controlprotocol
Example
ȩ
{rs232_link_prot=lw2}
Ȩ
(RS232_LINK_PROT=LW2)
INFO:
ThecurrentlocalRS-232parameterscanbequeriedbythe{RS232_LINK_PROT=?}command.