Troubleshooting Alarms
µSDM-1RD / µSDM-1 / µSDM-1E IOM
6-8
Lightscape Networks Ltd. Proprietary
426006-2304-013-B1
Table
6-1:
µµµµ
SDM-1 Transmission object maintenance operations
Menu Item
Function
Can be
performed on:
Near End Loopback Causes a loopback to operate on a specific TTP (trail
termination point). Near-end loopbacks are in the
direction of PDH traffic.
2M, RS, VC4
Far End Loopback
Causes a loopback to operate on a specific TTP (trail
termination point). Far-end loopbacks are in the direction
of SDH traffic.
2M, MS, VC4
Force AIS
Forces an AIS in the downstream direction.
2M, VC12, TU12,
MS, AU4
Force FERF
Forces a FERF in the upstream direction.
VC12, MS, VC4
Send Upstream AIS Forces an AIS in the upstream direction.
VC12, MS, VC4
Restart Processor
Resets the NE CPU.
CPU
6.3 Alarms Management
Lightscape Networks product line supports sophisticated mechanisms for detecting
malfunctions and generating alarms accordingly. The eEM provides the following
alarm categories:
Communications
Alarms
Alarms associated with the communications between the
eEM and an NE (i.e., Loss of Signal).
Equipment Alarms
Alarms associated with
µ
SDM-1 equipment card problems.
Transmission
Alarms
Alarms associated with transmission path problems.
Timing Alarms
Alarms associated with timing source problems.
In addition, the system supports
Quality of Service
(
QoS
) alarms which report the
crossing of performance thresholds. The system also logs the following events:
♦
Object state change
♦
Internal Alarm - connect/disconnect
♦
Internal Alarm - loss of events
The eEM's alarm management functions are accessed from the
Alarms
menu and
from the Faults
tab in the Options
dialog box.
The eEM uses the following visual and audible indicators in situations requiring user
intervention:
♦
In the Topology View, alarm bells that indicate that the NE is in an alarm
condition.
Содержание mSDM-1
Страница 16: ...Introduction SDM 1RD SDM 1 SDM 1E IOM 1 6 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 26: ...Product Description SDM 1RD SDM 1 SDM 1E IOM 2 10 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 100: ...Acceptance and Commissioning SDM 1RD SDM 1 SDM 1E IOM 7 6 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 109: ...426006 2304 013 B1 Lightscape Networks Ltd Proprietary B 1 Packing List A typical SDM 1 packing list...
Страница 110: ...Packing List SDM 1RD SDM 1 SDM 1E IOM B 2 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 122: ...Connector Pin Outs SDM 1RD SDM 1 SDM 1E IOM C 12 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 132: ...Rack Installation Guidelines SDM 1RD SDM 1 SDM 1E IOM E 4 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...