FEATURES AND SPECIFICATIONS
LEDS: 18, 6W each (Warm White, Cool White, 2in1)
Beam angle: 45° (25º optional)
Control system: DMX-512 + Stand Alone Modes
DMX channels: 1/2/3/4/5
DMX connectors: 3 pin XLR
Voltage: 120-240 VAC 50/60Hz
Max power consumption: 120 Watts
Ingress Protection: IP20 - Indoor Use Only
Refresh Rate: > 3000Hz
Color Temp.: 3200K - 7000K
Cooling: Intelligent Fan
Body material: Die Cast Aluminum
Body color: Black (White optional)
Size: 9.9"L x 9.9"W x 4.5"D (without brackets)
Weight: 12.5 lbs. (4.5kg)
DESCRIPTION
The FXLD618FR2I is a variable white LED lighting
fixture. It is suitable for stage, house of worship,
entertainment venues, and other artistic applications.
It has several stand-alone control modes and can
operate via a DMX512 external signal.
A double yoke enables the fixture to be operated in
several positions.
INSTALLATION
LOCATION
Locate the unit indoors in a well ventilated area away
from moisture and heat. Keep the vent holes clear.
Holes are provided on the yokes to install a lighting bar
pipe clamp. Use a safety cable when hanging the
fixture.
POWER CONNECTIONS
The FXLD618FR2I has a blue turn and lock connector
for power input. A compatible power cable is provided
for connection to a 120 VAC, 15 Amp, 60Hz, grounded
service. Push the blue connector on the cable straight
into the blue connector on the unit and twist approx.
1/8 turn clockwise to latch it.
The white turn and lock connector on the unit is used
to pass power on to another FXLD618FR2I unit. A
mating white connector is also provided.
THE LINE CORD IS RATED FOR 7 AMPS MAXIMUM
THE SAFETY GROUND TERMINAL ON THE POWER
CABLE MUST BE USED.
DMX CONNECTIONS
A system using DMX control should be connected as a
chain of devices. In other words, the control signal
cable proceeds from the controller to the first receiving
device and then to others in one continuous chain.
The fixture has a DMX IN and a DMX OUT connector
to be used to connect the chain. The control cable
should NOT be split into a multiple run star
arrangement with a cable running from the controller
directly to each receiving device.
DMX CONNECTOR PIN ASSIGNMENTS
The FXLD618FR2I receives a DMX signal on the 3 pin
MALE connector on one side of the unit. The 3 pin
FEMALE connector is used to connect the next DMX
device on the control chain.
PIN #
SIGNAL NAME
1
DMX COMMON
2
DMX DATA -
3
DMX DATA +
DMX TERMINATION
A DMX chain should be terminated at the last receiving
device on the chain. This is done by installing a
commonly available 1/4 Watt, 120 Ohm resistor across
the DATA - and DATA + wires at the last device. If you
have only a few fixtures very close together and a very
short run to the controller, then you may be able to
operate without the terminator.
CAUTION