background image

Ordering Information Explanation of Catalog Number. Example: WA4A232120SOGLR

A

FIXTURE
LENGTH:

4

=4' Length

8

=8' Length

2

LAMP

QUANTITY

For 4' Fixtures, 

2 Lamps

For 8' Fixtures, 

2 Lamps in Tandem

LAMP

32 

=T8, 4' Length

34 

=T12,  4' Length

VOLTAGE:

120 or 277

OPTIONS:

Add appropriate
suffix to catalog

no., ie: (GLR)

WA

LER = FS - 56.5  Watts - 63.0  BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.25

FIXTURE

WIDTH:

A

=9" Wide

DOMINAIRE II:

Surface Wrap

Fluorescent

With White Body

Photometry

Model No. WA4A232120SO

coefficients of utilization — zonal cavity method

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

77

74

71

68

66

64

64

63

61

2

71

66

61

60

57

54

57

55

53

3

65

59

53

54

50

47

52

48

46

4

60

52

47

49

44

41

47

43

40

5

55

47

41

44

39

35

42

38

34

6

51

42

36

39

35

31

38

34

30

7

47

38

32

36

31

27

34

30

27

8

43

34

28

32

27

24

31

26

23

9

40

31

25

29

24

21

28

23

20

10

37

28

22

26

21

18

25

21

18

visual comfort probability 

(VCP) average 100 fc; reflectances 80/50/20

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

61

65

72

77

60

65

71

78

20

30

54

58

63

69

53

57

63

69

20

40

51

53

58

62

50

53

58

62

20

60

47

50

53

57

46

50

53

57

30

20

62

66

71

76

61

65

71

76

30

30

55

58

62

66

54

57

61

66

30

40

51

53

56

60

50

53

56

60

30

60

48

50

51

54

46

49

51

55

30

80

46

48

48

51

44

47

48

52

40

20

63

67

71

76

63

67

72

76

40

30

56

59

62

66

56

59

62

66

40

40

52

54

56

59

51

53

56

59

40

60

49

50

51

54

47

49

51

54

40

80

47

48

48

51

45

47

48

51

40

100

47

47

46

49

44

46

46

49

60

30

58

60

63

67

57

60

63

67

60

40

53

55

57

60

53

55

56

59

60

60

50

51

51

54

48

50

51

54

60

80

48

48

48

50

46

47

48

50

60

100

47

47

46

48

44

46

46

48

100

40

57

58

59

62

56

58

59

62

100

60

53

53

53

56

51

53

53

55

100

80

50

51

50

52

48

50

49

51

100

100

49

49

48

49

47

48

47

49

room cavity ratio

luminaries lengthwise

luminaries crosswise

WA4A232120SO

LAMPS: TWO F32 T8, EACH RATED 2850 LUMENS

BALLAST TYPE:

1 & 2 Lamp Mag. T12

LE

<20THD <10THD

1 & 2 Lamp Elec. T8

SO*

H

I

*

1-4 Lamp Elec. T8

O4*

H4*

(8' Unit Only)
LOL T8 Dimming

PS

*

*

Instant Start Standard

REL-2P32-SC

DOMINAIRE II

WA SERIES 232

Page 2 of 2

SURFACE WRAPAROUND FLUORESCENT, 9" WIDE x 2 5/8" DEEP x 48" OR 96" LENGTHS

2 LAMP, T8 OR T12

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

Section 3A/Folio H90-12 Rev. B

Job Information

Type:

Options/Accessories

CANOPY SPACER: 

Spacer suspends fixture approximately 1 1/2" from surface.

Order Catalog Number: 

AC1 CSP.

STEM AND CANOPY SETS: 

Suspends fixture 6", 12", 18" or 24" from surface.

Order Catalog Number: 

ASC6 CSP 

(6"), 

ASC12 CSP 

(12"), 

ASC18 CSP 

(18"),

ASC24 CSP 

(24").

When stem mounting two or four lamp fixtures in continuous rows, umits must
be coupled with nuts and bolts (by others) at end of fixture. Stem and canopy
sets not recommended for three lamp fixtures. Other lengths are available.
Consult factory.

ELECTRICAL/WIRING OPTIONS: 

Consult factory.

FUSING: 

Internal fast-blow fusing. SUFFIX: 

GLR.

Internal slow-blow fusing. SUFFIX: 

GMF.

Specifications

PERFORMANCE: 

In an installation of 2 lamp 32W luminaires in a room cavity

ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall
not be less than .74. To reduce glare the VCP shall be not less than 48 either
lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall
not exceed 683 footlamberts To prevent veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 64.1%.

Specifications (continued)

MATERIALS: 

Chassis parts are die-formed code gauge cold rolled steel.

FINISH: 

Chassis exterior–white baked polyester enamel. Cavity– white baked

polyester enamel minimum 86% reflectance. Phosphate undercoating.

LENS: 

One-piece extruded virgin acrylic prismatic bottom and side walls.

END CAPS: 

Injection molded catadioptic end caps separate from lens.

ELECTRICAL: 

Thermally protected class “P” ballast C.B.M. approved, non PCB.

If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: 

I.B.E.W. UL and ULc Listed.

Отзывы: