SS Staggered Strip Surface Fluorescent
SS 2 LAMP
Page 2 of 2
4-1/4" Wide, 1-5/8" Deep, 27", 39", 51", 75", 99" Length, Individual or Tandem,
2 Lamp T8 or T12
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0403
Section3A/Folio H130-12
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: SS4S232HPF120SOGLR†
Options/Accessories
Fusing:
Internal fast-blow fusing. Suffix:
GLR
.
Internal slow-blow fusing. Suffix:
GMF
.
Electrical Wiring Options:
Consult factory.
Radio Interference Filter:
120 or 277 volt, 50 or 60 Hz. One per fixture.
Suffix:
R
. One per ballast. Suffix:
B
.
Stem and Canopy Sets:
Suspends fixture 6', 12', 18' or 24' from surface.
Catalog Number:
ASC6 CSP
(6"),
ASC12 CSP
(12"),
ASC18 CSP
(18"),
ASC24 CSP
(24").
Specifications
Materials: Chassis parts
are die formed heavy duty code gauge cold
rolled steel.
Ballast cover
–code gauge cold rolled steel, secured by plated quarter-turn
latches.
Finish: Chassis exterior
–baked white polyester enamel, minimum
reflectance 86%.
Electrical:
Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels:
I.B.E.W./UL and ULc Listed.
Photometry
Model No. SS4S232HPF120SO
Other dimming options. Consult factory.
Staggered Strip:
4-1/4" wide
channel
Fixture Length:
2
=27"
3
=39"
4
=51"
6
=75"
8
=99"
2
Lamp Quantity
Lamp Configuration:
S
=Standard
T
= 3' or 4' Lamps
in Tandem
(for 6' or 8' Units)
Lamps:
(By Others)
17
= 17 watt (T8)
20
= 20 watt (T12)
(Nominal 24")
25
= 25 watt (T8)
30
= 30 watt (T12)
(Nominal 36")
32
= 32 watt (T8)
34
= 40 watt (T12)
(Nominal 48")
(Two lamps in tandem
for 75" and 99" fixtures)
HPF
Ballast Type:
HPF
=High Power
Factor
Voltage:
120 or 277
Ballast:
1-2 Lamp Mag. T12
LE
Standard Electro-
Magnetic (20 or
30 watts only)
P
<20THD <10THD
1-2 Lamp Elec. (T8)
SO*
H
I
*
1-4 Lamp Elec. (T8)
O4*
H4*
LOL Dimming (T8)
PS
–
*
Instant Start Standard
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
SS
†No Product Change. New Catalog Number Designation.
REPORT NO: G89007
CATALOG NO: SS4S232HPF120SO
LAMP TYPE: 2F32 T8
LUMENS PER LAMP: 2850 TOTAL
EFFICIENCY: 89.5%
CIE TYPE: Semi-Direct
SPACING CRITERIA: 1.6
SHIELDING ANGLE: 180
coefficients of utilization — zonal cavity method
(effective floor cavity reflectance 0.20)
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
89
84
79
71
68
64
64
61
58
2
80
71
64
60
55
51
54
50
46
3
72
62
53
52
46
41
47
42
38
4
65
54
45
46
39
34
41
36
31
5
59
47
39
40
34
28
36
30
26
6
54
42
33
36
29
24
32
26
22
7
50
37
29
32
25
21
29
23
19
8
46
33
25
29
22
18
26
20
16
9
43
30
22
26
20
15
23
18
14
10
40
27
20
24
18
13
21
16
12
room cavity ratio
LER = FP - 38.7
IW - 58.0
BF - 0.87
Comparative yearly lighting energy cost per 1000 lumens = $6.20