INSTRUCTIONS FOR ATTACHING ADAPTER TO SINGLE 
CIRCUIT LYTESPAN TRACK:

1. Position LEVER as shown in Fig. 1.
2. Align GROOVE in ADAPTER with BEAD on TRACK. See Fig. 1.

(If GROOVE of ADAPTER is not placed over BEAD in
TRACK, a potential hazard may result.)

3. Insert ADAPTER into TRACK.
4. Rotate LEVER 90° while pushing upward on ADAPTER, to

make mechanical and electrical connection. See Fig. 2.

To remove or change fixture location on the TRACK, reverse 
procedure #4 above.

INSTRUCTIONS FOR CONVERTING POWERARC ATTACHMENT
FITTING TO OPERATE ON 2 CIRCUIT LYTESPAN TRACK:

NOTE: 

To insure proper operation of POWERARC on Two
Circuit  Lytespan Track, the BLACK SPACER (provided)
must be used at all times on the plug assembly. The
BLACK SPACER is not used when operating
POWERARC on Single Circuit Track.

LOWER CIRCUIT, Fig. 3 & 6:
Illustrates contacts in low position with spacer in place for
lower circuit.

UPPER CIRCUIT, Fig. 4, 5, & 6:
To convert attachment fitting for upper circuit, raise BRASS 
CONTACT to high position (as indicated by dotted line) by
pulling CONTACT as high as stop permits and slipping on
BLACK SPACER as shown in Fig. 4 & 5.

Do not try to move stationary silver contact.

AIMING ADJUSTMENTS:

CAUTION: ALLOW TIME FOR FIXTURE TO COOL BEFORE
MAKING ANY ADJUSTMENTS!

Rotate fixture both HORIZONTALLY and VERTICALLY to the
desired position. Fixture has horizontal and vertical rotation
stops (DO NOT FORCE FIXTURE PAST STOPS. DOING SO MAY
CAUSE AN ELECTRICAL HAZARD) See FIG. 7. For precise
VERTICAL rotation, rotate HEAD of fixture and line up desired
angle on the AIMING ANGLE INDICATOR with the INDICATOR
TAB (See FIG. 8).

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:8292

0203    

Page 1 of 2

INSTRUCTIONS FOR THE OPERATION AND ATTACHMENT OF POWERARC

TO A

LYTESPAN

®

TRACK SYSTEM. FOR USE WITH LYTESPAN TRACK SYSTEMS ONLY.

LIGHTOLIER a GENLYTE company.

631 Airport Road, Fall River, MA  02720

®

HORIZONTAL
ROTATION

FIG. 7

VERTICAL
ROTATION

FIG. 8

AIMING
ANGLE
INDICATOR

INDICATOR
TAB

HEAD

FIG. 1

LEVER

ADAPTER

GROOVE

BEAD

TRACK

ADAPTER

LEVER IN
ENERGIZED POSITION

FIG. 2

ADAPTER

FIG. 3

MOVABLE
BRASS
CONTACT

BLACK
SPACER

PLUG
ASSEMBLY

ADAPTER

PLUG

ASSEMBLY

STATIONARY
CONTACT
(Common)

MOVABLE
BRASS
CONTACT

FIG. 4

BLACK
SPACER

MOVABLE

BRASS

CONTACT

BLACK
SPACER

PLUG
ASSEMBLY

ADAPTER

FIG. 5

UPPER
CIRCUIT

LOWER
CIRCUIT

Common

FIG. 6

Отзывы: