G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional
T-grid ceiling (see options for
splay trim).
drywall kit. (See options)
1/4" max.
15/16"
or 1"
24"
24"
1/4" max.
3/8"
24"
Type “G”
Fixture
15/16"
Ceiling Opening
24-5/16" x 24-5/16"
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
13/16"
Plaster Opening
24-1/8"
24-11/16"
1-1/8" min.
3-3/4" max.
9/16"
24"
1-1/2" max.
1-7/8" max.
1-7/8" max.
1-1/8" min.
3-3/4" max.
23-7/8"
(606mm)
15-11/16"
(398mm)
Air supply slots
(MPA only)
2"x 2-1/2" access plate
with two K.O.s (7/8" dia.)
24" (610mm)
5" (127mm)
24" (610mm)
5" (127mm)
PARABAFFLE plus
MPA2G36LP32U or 17
Page 1 of 2
2'x2' RECESSED FLUORESCENT, 11/2" DEEP, 36 CELL PARABOLIC LOUVER,
STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, T8, 1-5/8"U LAMP OR 2' LAMP
Mounting Methods
Dimensions
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 2/Folio G20-14
Features
• 5" deep body.
• 3 1/2" x 3 1/2" cell size.
• 54.8% efficient (3-1 5/8" U Lamp).
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• Hemmed over side rails for safe handling.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• Pre-anodized aluminum parabolic louver.
• Vertical grain louver eliminates reflected lamp images on
cross baffle.
• Spring-loaded rooster head latches.
• 18 gauge steel hinges.
• Louver frame with integral positive light stop.
• Louver has protective film dust guard.