631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2012 Philips Group • D0412
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lytecaster Recessed Downlighting
302MRAICEX
Page 1 of 1
3 ¾" (95mm) Aperture Low Voltage 50W MR16 12V IC / Air Seal Electronic Frame-in-Kit
Complete fixture consists of Reflector Trim & Frame-In Kit. Select each separately
302MRAICEX
3 3/4" (95mm)
Accepts most 3 3/4" (95mm) 300 series trims ;
see Reflector Trim specification sheets.
Power Pack
Cut-Out
Reflector Trim
Features
1. Housing:
032" (#20 ga.) aluminum. CSA certified and UL Listed for direct
contact with thermal insulation. Airseal housing minimizes air leakage to less
than 2 CFM at 1.57 PSF (or 75pa), which complies with Model Energy Code
(Section 602.3.3) and Washing State Energy Code (Section 502.4) and reduces
heat loss and condensation in ceiling. Access door for inspection of junction box.
2. Mounting Frame:
.032 (#20 ga.) aluminum. Accommodates ceilings up to 1"
thick. 3/8" deep integral lip. Locks into position along length of mounting bars
with locking screw and bendable slot. Four slots are positioned 90º apart to
simplify alignment. Push-in/twist-out roto-clips hold reflector flush to ceiling.
3. Mounting Bars:
16 ga. galvanized steel. Extend from 14" (356mm) to 24"
(610mm). "SwiveLock" system permits installation and wiring below the
ceiling. Pre-installed No. 6 auger point screws for installation in wood and
steel joists. Attaches to T-bar ceilings without the need of accessories.
4. Junction Box:
2"( 51mm) x 4" (102mm) x 3 1/2" (89mm) 22 ga.galvanized
steel. Integral cable clamp permit attachment of non-metallic (#12 or#14 ga.)
cable without tools or additional connector.
5. Socket :
Porcelain body ; Two-pin (GX5.3 base) Pre-wired with 18 ga. Teflon
250° leads to junction box. Lamp cover: Aluminum heat deflector for 50W
MR16 / 37W MR16 IR.
6. Transformer:
Electronic, 60W Class 2, 120 volt primary, 11.75volts output
at max. load. RFI protection compatible with FCC limits. Electronic internal
resettable protection. Auto heat regulation that also automatically acts as
overload protection. Auto-reset thermal cut-off at 125C.
Dimming Controls
Use only dimmers specifically designed for use with transformers, like Lightolier
Onset, Sunrise series LV or VA dimmers, or any Lightolier Controls dimming
system. Low voltage fixtures may produce audible noise. Attention should be
given for noise sensitive applications.
Labels
Air Seal
Tested in accordance with ASTM E283 (max 2 cfm @ 75 pa) and comply
with WSEC & MEC when installed as instructed.
CSA, UL
Suitable for damp locations.