631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • D0211
Lytecaster Performance Recessed Downlighting
1101H
Page 2 of 2
6 ¾" Aperture Horizontal Open, Performance Series, Reflector Trim
Job Information
Type:
32W TRIPLE TUBE LAMP
, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
181
363
544
725
0
181
363
544
725
60˚
30˚
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens
%Lamp
%Fixt
** Efficiency = 61.7% **
0-30
516.68
23.5
38
0-40
827.14
37.6
60.9
0-60 1337.28
60.8
98.5
0-90 1357.97
61.7
100
90-120
0
0
0
90-150
0
0
0
90-180
0
0
0
0-180 1357.97
61.7
100
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 73 73 73 73 72 72 69 69 66 66 62
1 69 67 65 63 65 62 63 60 61 58 55
2 64 60 57 54 59 54 57 52 55 51 49
3 59 54 50 47 53 47 52 46 50 45 43
4 55 49 44 41 48 41 47 40 45 40 38
5 51 44 40 36 44 36 42 36 41 35 34
6 48 40 36 32 40 32 39 32 38 34 31
7 44 37 32 29 36 29 35 28 35 31 28
8 41 34 29 26 33 26 33 26 32 28 26
9 39 31 27 23 31 23 30 23 30 26 23
10 36 29 24 21 29 21 28 21 27 24 21
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
CANDLEPOWER SUMMARY
Angle
0˚ CP
90˚ CP
0
720
720
5
722
725
10
689
697
15
641
633
20
626
558
25
621
535
30
573
569
35
492
483
40
416
399
45
383
336
50
366
321
55
318
306
60
42
44
65
9
9
70
5
6
75
4
4
80
3
3
85
2
3
90
2
3
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
68.47
10-20
181.71
20-30
266.5
30-40
310.46
40-50
281.1
50-60
229.04
60-70
13.53
70-80
4.17
80-90
2.98
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
1
2
SC = 1.1
1 = 90˚
2 = 0˚
CERTIFIED TEST REPORT NO. 3166FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
100W ED-17 COATED METAL HALIDE
, LUMEN RATING = 7900 LMS, CL FINISH TRIM
CERTIFIED TEST REPORT NO. 4056FR
60˚
30˚
Coefficients Of Utilization
Ceiling
80%
70%
50%
30%
0
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 66 66 66 66 64 64 62 62 59 59 55
1 62 60 58 56 59 56 56 54 54 52 50
2 57 54 51 48 53 48 51 47 49 46 44
3 53 48 45 42 48 41 46 41 45 40 38
4 49 44 39 36 43 36 42 36 40 35 34
5 46 39 35 32 39 32 38 31 37 31 30
6 42 36 31 28 35 28 34 28 33 28 26
7 39 33 28 25 32 25 31 25 31 25 24
8 37 30 26 23 29 22 29 22 28 22 21
9 34 27 23 20 27 20 26 20 26 20 19
10 32 25 21 19 25 18 25 18 24 18 17
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Candlepower Distribution
0
45
90
0
1959
1959
1959
5
2033
1948
1955
10
2142
1913
1870
15
2120
1880
1842
20
2044
1835
1780
25
2160
1732
1713
30
1997
1687
1673
35
1826
1587
1577
40
1588
1403
1386
45
1432
1206
1159
50
1203
1027
1005
55
1087
944
896
60
215
178
167
65
41
37
46
70
30
24
13
75
10
31
12
80
12
21
24
85
10
12
9
90
16
13
7
Trim/Frame:
1101HCLHID
Lamp lumens:
7900 lm
Input Watts:
119W
Efficiency:
56.00 %
Spacing Criterion (0-180):
1.42
Spacing Criterion (90-270):
1.28
Multiple Unit Data - RCR 2
Spacing
Avg.Initial
Watts/
On Ctr.
Footcandles
Sq. Ft.
6'
106
2.97
8'
74
2.06
10'
47
1.32
38'x38'x10' Room, Workplane 2 1/2'
above floor, 80/50/20% Reflectances
Zonal Lumens And Percentages
Zone
Lumens
%Luminaire
0-30
1571
36.0%
0-40
2593
59.0%
0-60
4289
98.0%
0-90
4382
100.0%
500
1000
1500
2000
0
500
1000
1500
2000
Single Unit Data 100W 1101HCLHID
Height to
Initial
Beam
Lighted Plane
Footcandles
Diameter
8'
30
11'
10'
20
14'
12'
14
17'
14'
10
20'