Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems
PTS8-1
1BHFPG
1FSJNFUFS5SPVHI3FDFTTFE-JHIU51FS /PNJOBM4FDUJPO
%
Quarter Scale
Features
1. Housing:
Die-for
m
ed 20 gauge pre-painted steel. Integral heavy gauge bulk-
heads support housing and tri
m
, per
m
itting
m
odules to be bolted together in
continuous runs and facilitate suspension.
2. Lamping:
Continuous Rows:
1. Deter
m
ine run length.
2. Order the appropriate nu
m
ber of MODULES for the co
m
plete ROW.
3. Stagger rows
m
ust be co
m
pleted with an adjustable
m
odule.
4. Non-stagger rows
m
ust be co
m
pleted with an adjustable
m
odule unless row
lengths are in precise 1 foot (30.48c
m
) intervals.
5. Order one END SET per ROW.
Labels
UL, cUL and IBEW
Ordering Instructions
Individual Fixtures:
1. Order nu
m
ber of MODULES required.
2. Order one END SET per MODULE.
(2-light only)
3. Reflector:
Precision parabolic roll-for
m
ed se
m
i-specular alu
m
inu
m
.
4. Louver:
Lift and shift straight blade louver constructed fro
m
die-for
m
ed alu-
m
inu
m
and painted to
m
atch housing. Louver blades are 1” (2.54c
m
) high on
1-1/8” (2.86c
m
) centers. (Optional)
Mounting
“J” Rail is first
m
ounted to the wall and the
m
odules connect to the rail for 1/4”
(0.64c
m
) wall adjust
m
ent. Modules are hung fro
m
suspension wires attached to the
fixture bulkheads and the structure above.
Electrical
Electronic Ballast:
Progra
mm
ed start, 3 conductor, 12 gauge wire. Color-coded
quick connectors allow easy connection for
m
odular fixutres. Factory installed
ballast disconnect allows the ballast to be disconnected fro
m
and reconnected to
inco
m
ing power under load without turning the entire circuit off.
Dimming:
Advance Mark X, use Advance co
m
patible two-wire control (no extra
Emergency Battery Pack:
450 Lu
m
ens @ 90
m
ini
m
u
m
.
control lead required).
Cross-sectional one linear T8 fluorescent la
m
p. Provided by others.
Family
Lamps
Shielding
Voltage
PTS8
1
Length
Options
Blank
= No Options
A
= Adjustable*
X4
= 4 thru wires
X5
= 5 thru wires
A4
= Adjustable 4 thru wires*
A5
= Adjustable 5 thru wires*
1
= 1 La
m
p
O
= Open
L
= Lens
S
= Straight
Blade Louver
1
= 120V
2
= 277V
3
= 347V
D1
= 120V Di
m
.
D2
= 277V Di
m
.
E1
= 120V E
m
erg.
E2
= 277V E
m
erg.
Module Ordering Information
7"
(17.78c
m
)
9 3/8" (23.81c
m
)
5 1/2" (13.97c
m
)
1
3
4
2
* only available on Two-Foot, Three-Foot and Four-Foot versions. See length variations of adjustable fixtures on page 2.
2
= Two-Foot
3
= Three-Foot
4
= Four-Foot
6
= Six-Foot
8
= Eight-Foot