background image

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Lighting Systems

 

LSB-1

1BHFPG

-ZUFTQSFBEÜ-4#4PMJE*OEJSFDU-JHIU51FS'PPU /PNJOBM4FDUJPO

#

Features

1. Housing:

Extruded alu

m

inu

m

. Die-cast end-cap 

m

echanically attached with

no exposed fasteners or hardware. 

2. Lamping:

One T5, 28 or 54 watt (as specified) fluorescent la

m

p per 4-Foot

no

m

inal section. Provided by others.

3. Reflector:

Precision die-for

m

ed se

m

i-specular alu

m

inu

m

.

Electrical

Ballast is <10% THD, .98 ballast factor, pre-heat start. 18 gauge wire. Color-
coded quick connectors allow ease of connection for joiner 

m

odules. Power feed

is 18 gauge white SJT. For special circuiting consult factory. Factory installed
ballast disconnect allows the ballast to be disconnected fro

m

 and reconnected to

inco

m

ing power under load without turning the entire circuit off.

Dimming:

120/277 VAC 1% di

mm

ing level, 4 wire feed required.

Emergency Battery Pack:

28 watt: 520 lu

m

ens @ 90 

m

inutes, 54 watt: 700

lu

m

ens @ 90 

m

inutes.

Mountings

Finish

Powder coated baked white or alu

m

inu

m

 finish. Custo

m

 colors available, consult

factory.

Options and Accessories

E

m

ergency circuiting; special circuiting; X, T & L joiner blocks - consult factory.

Ordering Information

Fa

m

ily

La

m

ps

Voltage

Finish

1

= 1-La

m

p T5

4

= 4-Foot

A

= Solid

28

= 28W T5

AL

= Alu

m

inu

m

8

= 8-Foot

54

=  54W T5

WH

= White

5E

= 54W T5 E

m

ergency Pack

2E

= 28W T5 E

m

ergency Pack

5D

= 54W T5 Di

mm

ing

LSB

1

A

Length

Shielding

Ballast

= 120 volt

= 277 volt

Cable suspension (not shown) - 4-1/2" (11.43c

m

) dia

m

eter canopy finished white

ena

m

el, 1/16" (0.16c

m

) dia

m

eter stainless steel aircraft cable adjustable up to 36"

(91.44c

m

). Dual-screw draw-tight connector to create hairline sea

m

 between joiner

m

odules.

Co

m

plete ordering instructions below.

Labels

UL, cUL and I.B.E.W.

Ordering Instructions

Individual Fixtures:

1. Order nu

m

ber of MODULES required.

2. Order one POWER FEED END SET per MODULE.

Continuous Rows:

1. Deter

m

ine run length.

2. Order the appropriate nu

m

ber of MODULES for the co

m

plete run.

3. Order one POWER FEED END SET per run.
4. Order one CABLE ASSEMBLY per MODULE 

m

inus one per run.

5. For runs that exceed a

m

perage li

m

its, order the appropriate 

nu

m

ber of CABLE/CORD ASSEMBLIES.

Fixture Shown Half Scale

2

1

3

8-1/2” (21.59c

m

)

1-3/4" (4.45c

m

)