4 1/2" X 4 1/2" Square Aperture (1) 26/32W Triple Tube

Job Information 

Type:

20% Floor Cavity Reflectance

  1  .60  .59  .58  .59  .58  .57  .57  .56  .55  .55  .54  .53  .53  .52  .52  .51

  2  .56  .54  .52  .55  .53  .52  .53  .52  .50  .52  .51  .49  .50  .49  .48  .47

  3  .52  .49  .47  .51  .49  .47  .50  .48  .46  .49  .47  .45  .47  .46  .45  .44

  4  .48  .45  .43  .48  .45  .43  .47  .44  .42  .45  .43  .42  .44  .43  .41  .40

  5  .45  .41  .39  .44  .41  .39  .43  .41  .38  .42  .40  .38  .42  .40  .38  .37

  6  .42  .38  .36  .41  .38  .35  .40  .37  .35  .39  .37  .35  .39  .36  .35  .34

  7  .38  .35  .32  .38  .34  .32  .37  .34  .32  .36  .34  .32  .36  .33  .31  .31

  8  .35  .32  .29  .35  .31  .29  .34  .31  .29  .34  .31  .29  .33  .31  .29  .28

  9  .32  .29  .26  .32  .29  .26  .31  .28  .26  .31  .28  .26  .30  .28  .26  .25

10  .30  .26  .24  .29  .26  .24  .29  .26  .24  .28  .25  .23  .28  .25  .23  .23

32W Triple Tube, Specular Clear Reflector Trim

One Philips lamp, 2400 lumens

ZONAL LUMENS AND PERCENTAGES

Zone 

Lumens 

% Lamp 

% Luminaire

0-30 

628 

26.18 

 

47.89

0-40 

1002 

41.77 

 

76.42

0-60 

1309 

54.56 

 

99.82

0-90 

1311 

54.66 

100.00

712 

712  712  712 

712

721 

735  761  772 

773 

72

10 

710 

745  803  840 

828

15 

685 

727  808  835 

812 

220

20 

629 

678  765  849 

855

25 

557 

611  745  853 

844 

336

30 

485 

560  724  834 

823

35 

408 

493  629  718 

732 

374

40 

313 

392  500  574 

636

45 

220 

258  297  404 

472 

252

50 

123 

136  141  199 

224

55 

18 

31 

47 

53 

38 

55

60 

4

65 

2

70 

1

75 

0

80 

0

85 

0

90 

0

Test Report 

 

1710FR  

 

Apr. 4, 2002

Angle  Along  22.5  45  67.5  Across  Lumens

CANDLEPOWER SUMMARY

EFFICIENCY = 54.7% 

 Spacing Criterion: Along = 1.1  Across = 1.5

% Effective Ceiling Cavity Reflectance

  1  .60  .59  .58  .59  .58  .57  .57  56  .55  55  .54  .54  .53  .53  .52  .51

  2  .56  .54  .52  .55  .53  .52  .53  .52  .51  .52  .51  .49  .50  .49  .48  .48

  3  .52  .50  .47  .51  .49  .47  .50  .48  .46  .49  .47  .46  .48  .46  .45  .44

  4  .49  .46  .43  .48  .45  .43  .47  .44  .43  .46  .44  .42  .45  .43  .42  .41

  5  .45  .42  .39  .45  .42  .39  .44  .41  .39  .43  .40  .39  .42  .40  .38  .37

  6  .42  .39  .36  .41  .38  .36  .41  .38  .36  .40  .37  .35  .39  .37  .35  .34

  7  .39  .35  .33  .38  .35  .33  .38  .35  .33  .37  .34  .32  .36  .34  .32  .31

  8  .36  .32  .30  .35  .32  .30  .35  .32  .30  .34  .31  .29  .34  .31  .29  .29

  9  .33  .29  .27  .33  .29  .27  .32  .29  .27  .32  .29  .27  .31  .28  .27  .26

10  .30  .27  .24  .30  .27  .24  .30  26  .24  .29  .26  24  .29  .26  .24  .23

ROOM CA

VITY RA

TIO

cu

50  30  10  50  30  10  50  30  10  50  30  10  50  30  10  0 

    

80   

 

70   

 

50   

 

30   

 

10   

26W Triple Tube, Specular Clear Reflector Trim

One Philips lamp, 1800 lumens

ZONAL LUMENS AND PERCENTAGES

Zone 

Lumens 

% Lamp 

% Luminaire

0-30 

491 

27.29 

50.06

0-40 

768 

42.69 

78.31

0-60 

980 

54.47 

99.91

0-90 

981 

54.52 

100.00 

 

 

 

546 

546  546  546 

546

569 

576  577  573 

572 

55

10 

580 

592  616  644 

631

15 

552 

575  659  651 

623 

173

20 

492 

540  623  663 

635

25 

428 

486  588  676 

647 

263

30 

373 

428  567  642 

584

35 

320 

370  472  515 

508 

277

40 

254 

299  342  407 

456

45 

179 

198  189  272 

302 

176

50 

95 

107 

98  116 

123

55 

14 

23 

32  29 

20 

36

60 

2

65 

1

70 

0

75 

0

80 

0

85 

0

90 

0

Test Report 

 

1763FR  

 

Apr.5, 2002

Angle  Along  22.5  45  67.5  Across  Lumens

CANDLEPOWER SUMMARY

EFFICIENCY = 54.5% 

 Spacing Criterion: Along = 1.1  Across = 1.4

% Effective Ceiling Cavity Reflectance

ROOM CA

VITY RA

TIO

cu

50  30  10  50  30  10  50  30  10  50  30  10  50  30  10  0 

    

80   

 

70   

 

50   

 

30   

 

10   

20% Floor Cavity Reflectance

Based on specular clear (CL) finish. To estimate other finishes, multiply candelas 
and CU values by 0.95 for CCL, by 0.90 for CCD.

Отзывы: