Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

Calculite

®

 Evolution Incandescent Open Downlight 

C6AD

Page 1 of 2 

6" Aperture A19 / A21 / BT15 / MB19 Reflector Trim

8

7

6

5

4

3

2

1

Perspec. Drawing Nos. 

Calculite Evolution

Ceiling Cutout: 6 11/16" Dia.

Reflector Trim 

Frame-In Kit

C6AD CLW

 

Specular Clear, White Flange 

  Shallow 

Shallow 

Shallow 

Deep 

 

Deep 

Deep

C6AD CLP

 

Specular Clear, Polished Flange 

  Non-IC 

Non-IC AirSeal

®

 

IC-AirSeal

®

 

Non-IC   Non-IC AirSeal

®

 

IC-AirSeal

®

C6AD 

 

Add suffix. See options for other finishes.  

C6120 

C6A120 

C6AIC 

C6D120   C6DA120 

C6DAIC

 

 

 

 

100W A19, MB19 

 

100W A19, BT15, MB19 

100W A19, MB19

 

 

 

 

100W BT15 

 

150W A21   

100W BT15

 

 

 

 

 

 

 

 

150W A21

14 1/4" 

10" 

8 1/2" 

(10 1/4")

(18 1/8")

(13 1/2")

IC AirSeal

®

C6AIC / (C6DAIC)

Non-IC AirSeal

®

C6A120 / (C6DA120)

Non-IC

C6120 / (C6D120)

(24 1/4" O.A.)

(17 3/8"O.A.)

(9 1/8")

7 3/4" 

9 1/2" DIA. 

(12 1/4" DIA.)

(15 3/4")

 (15 3/8" O.A.)

  (9 1/8")

(12 1/4" DIA.)

20 1/4" O.A.

Included)

(Mounting Bars

Adjustment

Included)

(Mounting Bars

Adjustment

13 3/4" TO 24"

9 1/2" DIA. 

14 3/8" O.A.

7 3/4" 

12 1/2"

12 3/8" O.A. 

13 3/4" TO 24"

Note: Dimensions in parentheses refer to the C6D series deep Frame-In-Kits.

Features

1. Reflector:

 16 ga. aluminum, 50° visual cut- off to lamp and lamp image, 

medium spread distribution. Available with painted white or polished 
flange. Interchangeable with other Evolution 6” line voltage trims.

2.  Socket Harness:

 Spring tension clips snap into die-cast aluminum top 

at pre-focused positions insuring correct optical alignment. Medium base 
porcelain socket with nickel plated screw shell, No. 18 SF-1 leads to keyed 
plug-in quick connector for power connection to junction box.

3. Frame-in-Kit:

 Compatible frame-in kits are listed above. See separate 

frame-in kit specification sheets for details. 
Non-IC and Non-IC AirSeal

®

 - Insulation must be kept 3” away from fixture 

sides and wiring compartments and must not be placed above fixture in a 
manner which will entrap heat. 
IC-AirSeal

®

 - Fixture may be in direct contact with insulation.

Options & Accessories

Reflector Finishes

1

Clear: CL
Comfort Clear Diffuse:  CCD
Champagne Bronze: 

CCZ

Gold: 

GD

White: WH

1

Specify desired flange: 

W

 White, 

P

 Polished

Labels

UL Listed (suitable for damp locations), I.B.E.W.

1

3

2

C6 series

**11 1/8"min. is for up to 3/4" thick ceiling.

C6ADCLW / C6D120  or C6ADCLW / C6DA120

C6ADCLW / C6120 or C6ADCLW / C6A120

     8" 

(10 3/8" )

6" Dia.

7 1/4" Dia.

*8 3/4"min. is for up to 3/4" thick ceiling.

1/2" to 1 1/4" Max. Ceiling Thk.

(11 7/8" max.)

(11 1/8" min.)**

C6 series

9 1/4" max.

8 3/4" min.*

(C6ADCLW / C6DAIC)

(11 1/4")

C6ADCLW / C6AIC

 1/2" to 1" Thk. Ceiling

9 1/4"