4
9 1/2" Dia.
Adjustment
(mounting bars
included)
13 3/4" to 24"
7
6
5
2
3
1
9 1/4" max.
8 3/4" min.* 8"
7 3/4"
12 3/8"
1 1/4" Max. Ceiling Thk.
C6A120
*8 3/4" min. is for
up to 3/4" thick ceiling.
Ceiling Cutout: 6 11/16" Dia.
Frame-In Kit
Reflector Trim
C6A120
Open
Open Adjustable Open Lensed
Downlight
Downlight
Accent
Wall Washer/Downlight
Wall Washer
C6AD C6P30D C6P30A
C6AW C6P30L
100W A19, MB19
75W PAR30
75W PAR30
100W A19, MB19
75W PAR30
100W BT15
(Short Neck)
(Short Neck)
100W BT15
(Short Neck)
Calculite
®
Evolution Recessed Downlighting
C6A120
Page 1 of 1
6" Aperture Incandescent 120V Non-IC AirSeal
®
Frame-In Kit
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Thomas Group LLC (Lightolier Division) • B0711
FEATURES
1. Housing:
Steel, 0.03" (22 ga.). Top Cover: Aluminum, 0.04" (14 ga.). Matte
black finish. AirSeal
®
housing minimizes air leakage to less than 2CFM at
1.57 PSF (or 75pa).
2. Mounting Frame:
Die-cast aluminum for dry or plaster ceilings. Locks into
position along length of mounting bars with locking screws.
3. Retaining Springs:
Precision-tooled steel springs secure reflector trim to
mounting frame for quick, tool-less installation.
4. Mounting Bars:
Galvanized steel, 0.06" (16 ga.). Bars pivot for easy instal-
lation and wire-in below ceiling line. Bars extend to accommodate 16" to 24"
O.C. joist spacing. Bars can accommodate 12" O.C. joist spacing after a slight
field modification (see instruction sheet). Integral self-tapping screws for
securing to wood or metal construction. Built-in tabs for locking to T-bars
without the need of accessories.
5. Snap-In Connectors:
Keyed to accept power and socket harnesses which
are provided with reflector trim.
6. Junction Box:
Galvanized steel .063" (14 ga.). UL Listed for maximum of 8
No. 12 AWG 90°C through branch circuit conductors. Accessible from inside
and outside of fixture. Outside J-Box door is hinged for maximum opening.
Snap-in plug is provided on inside cover for quick connection to power
harness.
7. Thermal Protector:
Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be
placed above fixture in a manner which will entrap heat.
8. Reflector Trim:
Compatible reflector trims are listed above. See separate
reflector trim specification sheets for complete catalog numbers and details.
Options & Accessories
Chicago Plenum
Consult Factory
Labels
UL Listed (suitable for damp locations), I.B.E.W.