background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

GASKET

CLEAT

MULLION

OUTLET BOX SCREWS

MOUNTING PLATE
CANOPY

1/4-20 BOLTS

CLEAT

FIG. 1

FIG. 2

FIG. 3

FIG. 4

  CAUTION: 

For wet locations, in accordance with Underwriters Laboratories  

  requirements, a line of caulking compound such as acrylic or silicone must be 
  placed around the perimeter of CANOPY to seal water away from the  
  outlet box and back openings. 

 
INSTALLATION OF WALL CYLINDER TO OUTLET BOX  
(Fig. 1, 2, 3, & 4)

 

 

STEP 1:

  Attach MOUNTING PLATE to outlet box with OUTLET BOX 

SCREWS. 

 

STEP 2:

  

Pass supply leads through opening in CANOPY and CLEAT. 

 

STEP 3:

 

 Attach CANOPY, CLEAT/GASKET to MOUNTING PLATE with (2) 

¼-20 BOLTS.

 

 

STEP 4:

  

Make Connections.  Bare Copper and/or green insulation wire(s) 

must be connected to SUPPLY GROUND.  Connect WHITE BALLAST LEAD 
to NEUTRAL (WHITE) SUPPLY LEAD.  Connect BLACK BALLAST LEAD to 
HOT SUPPLY LEAD.  Use wire nuts (local hardware items).  

 

STEP 5:  

Install SET SCREWS loosely.  Place cylinder over CLEAT and 

tighten (2) SET SCREWS. 

 
 

INSTALLATION OF WALL CYLINDER TO POST OR OTHER 
VERTICAL SURFACE MOUNTING (Fig. 2, 3 & 4) 

 

STEP 1:  CLEAT can also be mounted directly to any flat surface 
such as MULLION. In this case, use of CANOPY is optional.  Bring 
supply leads through CLEAT and install CLEAT to wall. For wet 
locations, in accordance with Underwriters Laboratories requirements,
a line of caulking compound such as acrylic or silicone must be 
placed around the perimeter of EXTRUDED ARM  to seal water away 
from the wireway and back openings.

 

 

STEP 2:

  

Proceed with Step 4 and 5 above.  

 
 

INSTALLATION OF REFLECTOR TRIM TO CYLINDER (Fig. 4)

 

Follow installation instructions in Reflector Trim Instruction Sheet IS:C4T4V. 

 

CAUTION:   

 

DO NOT ENERGIZE THE LAMP UNTIL REFLECTOR  

       TRIM IS COMPLETELY INSTALLED. 

 

 

INSTALL ONLY T-6 TUBULAR SINGLE-ENDED  

 

CREAMIC ARC TUBE METAL HALIDE LAMP.  

 

 

 

COMPANY

631 Airport Road, Fall River, MA 02720 

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 

assure full compliance with local codes and regulations, check with your local electrical inspector before 

installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:C6CW 

Page 1 of 2

A0604 

INSTALLATION PROCEDURE FOR: C6CW SERIES 6” DIA. H.I.D. WALL MOUNT CYLINDER 

USED WITH C6T6V SERIES FLANGLESS REFLECTOR TRIM (ORDER SEPARATELY) 

WARNING: 

USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURES’ REFLECTOR 

TRIMS MAY VOID THE UNDERWRITERS LABRATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.

 