Features

1.  Housing: 

23gaugepre-paintedsteel.20gaugeavailable,consultfactory.

2.  Lamp: 

OneT8.(byothers)

3.  Faux Housing: 

ExtrudedFrostyacrylic.

4.  Louver:

HighpuritySemi-Specular,2-3/4"(6.99cm)openingx1-3/8"(3.49cm)

deepon2"(5.08cm)ctrswithmicro-prismaticsideoverlays.Elongatedlens
openingsare22"(55.88cm)windows.

5.  Performance Kick Reflector:

.020"(0.05cm)95%-98%reflective,UV

resistant polypropylene.

6.  Trim:

Extrudedaluminumtrim,paintedwhite,interfaceswithceilinggridor

plasterframebyothers.

Electrical

Ballastsareelectronicandhighpowerfactor.Dimmingballastsareavailableon
manylamptypes,pleaseconsultfactoryregardingspecificapplications.1325
maxlumenbatterypackisstandard.Seeapplicationtableonpage2foroutput
with specific lamp types.  Continuous luminaires utilize 12 gauge through wires. 
Factoryinstalledballastdisconnectallowstheballasttobedisconnectedfromand
reconnected to incoming power under load without turning the entire circuit off.

Mounting

Housingissuspendedbyhangerwiresandlaidintostandardorslot-Tgridceiling.
Mountingaccessoryavailablefordrywallinstallations(seepage2).

Labels

UL,cULandI.B.E.W.

Ordering Instructions

Individual Fixtures:
1.

 OrderquantityofIndividualUnitsrequired.

Continuous Runs:
1.

 OrderoneStarterandoneEnderfixtureperrun.

2.

 OrderappropriatequantityofJoinerfixtures.

Continuousrunsonly-PriortoinstallingAlettainagridceiling,theinstalling
contractormustensurethatthefixturewillsetintotwomainrunners,spaced2'
(60.96cm)oncenter.Nogridcrossmembersarerequiredexceptatthebeginning
and end of the run.

7.00”

(17.78cm)

23.00”

(58.42cm)

2.00”

(5.08cm)

2.75”

(6.99cm)

24.00” (60.96cm)

5.28”

(13.41cm)

7.00”

(17.78cm)

1

2

5

3

4

6

Louver w/ Elongated 

Lens Detail

* For dimming, use "D" option. If "D" is not selected, ballast will be static.

Ordering Information

Family

Shielding

Length

Lamps

Lamp Type

Ballast Factor

Voltage

Housing

Option

A

1

T8

Aletta

LE

=Louverw/

Elongated Lens

2

=2'(60.96cm)

4

=4'(121.92cm)

= 1 Lamp

T8 

=T8

Standard 
Output

71 

= .71

78 

=.78

88 

=.88

10 

= *1.0 Dimming

and Static

12 

= *1.2 Step Dimming

= 120v

= 277v

=347v

=IndividualUnit

= Starter

= Joiner

= Ender

= Dimming

 

=EMPack

= 2 Circuit

=4ThroughWire

=5ThroughWire