background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1  FRAME-IN KIT INSTALLATION:

 See Frame-In Kit Instruction Sheet for installation procedure.

 

2 GASKET 

INSTALLATION:

  

A.  Align open side of gasket towards socket cup (figure A).  
B.  Pinch gasket and insert both edges under the reflector spring clip and align inner diameter 

to socket (figure B).   

C.  Push center of gasket until seated over socket and perimeter of gasket is just inside the 

socket cup (figure C).   

D.  Large internal diameter should fit over the lamp socket, small internal diameter sits on top 

of socket (figure D). 

 

 

Figure A

 

 

Figure B

 

 

Figure C

 

 Figure D 

CAUTION

 – DO NOT STRETCH SMALL INTERNAL DIAMETER OF GASKET OVER LAMP SOCKET. 

THE GASKET MUST SIT ON TOP OF SOCKET TO PROVIDE SEAL TO LAMP.

 

3 SNAP 

ON:

  

Insert gasketed socket cup into neck of reflector making sure spring clips of 
socket cup snap into slots of reflector (figure E). 

 

Figure E 

4 PUSH 

UP:

   

Push reflector trim straight up into fixture housing until it is tight against ceiling 
(figure F). 

 

Figure F 

 Note:  To remove reflector trim, squeeze reflector spring clip from inside until 

the trim disengages.  To retrieve socket cup, pull on one of the socket cup 
spring legs to disengage (figure G). 
 
Replacement Gasket Available: 

Lightolier Catalog No. LFG356

 

 

Figure G 

 

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 

assure full compliance with local codes and regulations, check with your local electrical inspector before 

installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 

Retain these instructions for maintenance reference.

INSTALLATION PROCEDURE FOR:

 

1181WH, 1181CD, 1081WH, 1081CD

 

1181WH and 1181CD for use with 1104, 1104R, 1104IC and 1104ICR only. 
1081WH and 1081CD for use with 1004, 1004R, 1004IC and 1004ICR only. 

CAUTION: (RISK OF FIRE) 

FOR NON-IC RATED INSTALLATIONS, DO NOT INSTALL INSULATION ABOVE  

OR WITHIN 3 INCHES OF ANY PART OF FIXTURE. 

 

CAUTION: 

USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURER’S REFLECTOR 

TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.

 

INSTRUCTION SHEET NO.

IS:1181 

B1104 

Page 1 of 1

 

COMPANY

631 Airport Road, Fall River, MA 02720 

CAUTION: 

BEFORE INSTALLING REFLECTOR TO FRAME-IN-KIT, READ MARKINGS IN REFLECTOR AND IN SOCKET CUP 

OF FRAME-IN-KIT TO DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION. 

 