This  manual  contains im portant la ser s ystem sa fety  and  operation 
information. Read and understand all instructions prior to powering on 
laser unit the first time, to avoid laser eye injury and to avoid breaking 
the law. Keep this manual in a safe place for future reference.

 

Содержание Phantomrgb1700

Страница 1: ...im portant la ser s ystem sa fety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this manual in a safe place for future reference ...

Страница 2: ...from laser incident or damage Prevent damage or injury from incorrect operation Laser safety warming labels To protect the environment recycle packing material wherever possible The projector is for indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact with water or any other fluids or metallic objects Don ...

Страница 3: ...ble parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact the dealer nearest to you Caution Use of c ontrols or a djustments or p erformance of procedures other than those specified herein may result in hazardous radiation exposure NON INTERLOCKED HOUSING WARNING This unit contains high power laser devices i...

Страница 4: ...products split the laser into hundreds of beams or laser beam is scanned out in high speed that an individual laser beam is safe for eye exposure This laser product uses dozens of milliwatts of laser power Class 4 levels internally Many of the individual beams are potentially hazardous to the eyes It is also incorrect to assume that because the laser light is moving it is safe This is not true Nor...

Страница 5: ... or open or if optics appear damaged in any way Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury Never leave this device running unattended The operation of a Class 4 laser show laser is only allowed if the show is controlled by a skilled and well trained operator familiar with the data included in...

Страница 6: ... LASER EMISSION DATA As measured under IEC measurement conditions for classification Laser Classification Class 4 Red Laser Medium LD GaAlAs 650nm typical Green Laser Medium DPSS Nd YVO4 532nm Blue Laser Medium LD GeAs 450nm typical Beam Diameter 5mm at aperture Pulse Data All pulses 4Hz 0 25sec Divergence each beam 2 mrad Divergence total light 40 degrees Cooling TEC Fan Cooling Scanning ILDA Sta...

Страница 7: ... any unauthorized modification to the device Please consider that damages caused by manual modifications to the devise are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug ...

Страница 8: ...ting the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others The minimum distance between the fixture and surrounding walls must be more than 50cm Always fix the fixture with an appropriate safety rope Fix the safety rope at the safety r...

Страница 9: ...t the fixture be returned in the original factory box and packing What is included The carton or flight case contain following items Power Supply To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture of refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All f...

Страница 10: ...ed with 2 pin XLR sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection Caution At the laser fixture the DMX cable has to terminated with a terminator Solder a 120 Ohm resistor between Signal...

Страница 11: ... Solder a 120 Ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pins XLR plug and plug it in the DMX output of the last fixture Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or ...

Страница 12: ...opriate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 2 5 meters of horizontal separation is required between laser light and audience...

Страница 13: ...o make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year The fixture should be installed in the position where persons can...

Страница 14: ...vance of this manual or any unauthorized modification to the device Features STABLE TE COOLED LASER DIODE CNI HIGH SPEED 40KHz SCANNER 2 x AUTO SHOW 2 x MUSIC SHOW 86 ANIMATED GRAPHIC SHOW PATTERNS HUNDRES PREPROGRAMED BEAM EFFECT MULTIMODE REAL WAVE EFFECT PERFECT WHITE COLOR BALANCE LCD CONTROL MONITOR SMART PRESS BUTTON CONTROL PANEL AUTO SELF CHECKING SYSTEM AUTO SOUND DMX ILDA 2 DMX MODES 13D...

Страница 15: ...n power indicated LED Red is ON 2 MUSIC Synchronize to detected music signal 3 L aser output Laser output aperture 4 H ANDING BAND Product handing band 5 HANGING BRACKET with 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting hook ...

Страница 16: ...s Setting 9 Urgent and safe switch Switch off the laser manually if error occurs 10 SD card Storage RAM SD MMC storage RAM less than 2G 11 K ey switch Make sure the professional person use 12 Coolin g fan Cooling and never cover this fan outlet 13 DMX output 3PIN Female XLR port using for DMX 14 DMX input 3PIN Male XLR port using for DMX 15 Sa fety eye Attach the safety cable ...

Страница 17: ...ize of Y axis adjustment 19 ILD A THROUGH Standard ILDA DB25 Output through 20 ILD A INPUT Standard ILDA DB25 Input 21 IL DA ILDA connection indicator LED Red is connection and green is disconnection 22 R G B Laser beam output indicator LED 23 MIC Microphone Turn the knob to adjust the sound activated sensitivity 24 LCD control Panel Intelligent LCD control panel of the system ...

Страница 18: ...problems stop using the fixture and contact your dealer immediately Attention Laser Saf ety Sc anner Bo ard is in cluded in th e system The Laser light will be turned off when the scanned angle is less than 1 degree Operating Mode Attention On ce af ter e very p ower on laser th e VERSION an d MANUFACTURE IN FORMATION will be s hown i n LCD monitor of rear panel When laser is powered on LCD monito...

Страница 19: ...ANUAL 18 Mode Option to choose the operating mode of laser Confirmation to confirm the laser to show the present mode at the next operation UP DOWN to change operating mode parameter or DMX address OPERATION ...

Страница 20: ...wn on LCD monitor The laser is set at AUTO SHOW 2 standalone mode and it will play the preprogrammed show until next setting is changed AUTO SHOW 2 is slow and soft show which is better for MUSIC BAR Press ENTER to confirm the laser to show the present mode at the next operation MUSIC SHOW 1 Press FUNC to enter MODE OPTION Till to MUSIC SHOW 1 shown on LCD monitor The laser is set at MUSIC SHOW 1 ...

Страница 21: ...older the folder name have to be 8 characters including letter or numbers Any folder name with more than 8 characters can not be displaced on LED monitor Press ENTER to choose the folder Press UP DOWN to choose show mode ILDA single show or PRG preprogrammed show Press ENTER to confirm the laser to show the present mode at the next peration Attention Please put ild format laser show in SD card onl...

Страница 22: ...NIMA TXT to ANIMA PRG IMPORTANT NOTES A NIMA1 ild is t he il d sh ow name 12 is scanner speed 3 is how many times you want this show to repeat DMX MODE Press FUNC to enter MODE OPTION Till to DMX address shown on LCD monitor Press UP DOWN to change the DMX address that you wanted Press ENTER to confirm the laser to show the present mode at the next operation Attention When the laser is connected w...

Страница 23: ...ll color show MIRROR MODE Press UP DOWN to change scanned world mirror UP is for Y direction mirror setting and DOWN is for X direction mirror setting MUSIC MODE To set the sensitivity of SOUND mode ILDA Control Mode This unit has the ILDA DB25 port and it can be controlled by the PC There is auto transform set in the inside of the unit to transform the ILDA and preprogrammed show when connecting ...

Страница 24: ...SHOW 2 222 255 DMX MODE Other channels activated PRG or ILD mode CHANNEL VALUE DESCRIPTION CH 2 000 255 Folders CH 3 000 255 Shows PRG or ILD DMX PATTERN MODE CHANNEL VALUE FUNCTION CH 2 PATTERN 000 255 86 Patterns as shown in PATTERN LIST Several optio nal ope rating mode s were pre programmed s et into this laser projector at DMX ch annel 1 Befo re control other DMX ch annels please be sure that...

Страница 25: ...245 Random position 246 255 Sound to random position CH6 Zooming 000 010 Original size 011 100 Fixed Sizing 101 150 Zooming out 151 200 Zooming in 201 255 Zooming out and in CH 7 Y AXIS ROLLING 000 010 No rolling 011 110 Fixed rolled position 111 255 Rolling from slow to fast CH 8 X AXIS ROLLING 000 010 No rolling 011 110 Fixed rolled position 111 255 Rolling from slow to fast CH 9 Z AXIS ROLLING ...

Страница 26: ...33 Red 034 050 Green 051 067 Blue 068 084 Yellow 085 101 Purple 102 118 Cyan 119 135 White red green blue 4 fixed colors 136 152 Blue yellow purple cyan 4 fixed colors 153 169 Severn colors 170 186 White red green blue 4 colors looping 187 203 Blue yellow purple cyan 4 colors looping 204 220 Severn colors looping 221 237 Original color 238 255 Color changing to sound CH13 000 063 Original pattern ...

Страница 27: ...USER MANUAL 26 PATTERN LIST DMX 000 050 051 101 102 152 153 203 204 254 255 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ...

Страница 28: ...dition Temperature DMX Connections DMX Channels Measurement N Weight AC100 240V 50 60Hz 250V 1 6A Slow Blow 20mm Glass 68W 20 Audio Sound Activated Class 4 EN60825 1 2007 10 40 3 pins XLR Male Female Max 13 channels See picture below 11 5Kg Every information is subject to change without prior notice The availability of particular products may vary by region Please check with the dealer ...