background image

Guardrail System 

Model Numbers:

RoofStep 5x5 XS, RoofStep 5x4 XS, 

RoofStep 5x3 LD, RoofStep 5x2 LD, 
RoofStep 5x1 LD, RoofStep 4x4 XS, 
RoofStep 4x3 LD, RoofStep 4x2 LD, 
RoofStep 4x1 LD, RoofStep 3x3 XS, 

RoofStep 3x2 LD, RoofStep 3x1 LD

.C

NI

N

O

I

T

C

E

T

O

R

P

L

LA

F

LIFTSAFE

Installation Manual: 

 

RoofGuard RoofStep Ladder Series
RoofGuard RoofStep Crossover Series
Gargoyle Ladder Series
Gargoyle Crossover Series

This Installation Manual is intended to meet the Manufacturer’s Instructions requirements and should be used as part of 

an employee training program.

WARNINGS AND CONDITIONS

These instructions must be provided to the installer of this system. The installer must read and understand these 

instructions and follow.

Failure to follow these instructions or the details of the unique layout drawing provided may result in serious injury or 

death. If you have any questions about this system’s use or care, please contact the manufacturer: 1-800-977-2005.

RoofStep Ladder Series Systems, RoofStep Crossover Series Systems, Gargoyle Ladder Series, Gargoyle 
Crossover Series Manual RGC-RS

Содержание RoofStep 3x1 LD

Страница 1: ...ded to meet the Manufacturer s Instructions requirements and should be used as part of an employee training program WARNINGS AND CONDITIONS These instructions must be provided to the installer of this...

Страница 2: ...T stand or climb on the railing DO NOT use rail as a tie off point DO NOT use rail for lifting or hoisting DO NOT install railing within 10 feet of any electrical lines DO NOT use if any component is...

Страница 3: ...Figure 1 Component Identification Failure to Read Understand and Follow the Installation Manual may result in injury or death WARNING...

Страница 4: ...adder support posts must be 6 2 4m from any parallel fall hazard edge Each system comes with a unique layout drawing with details specific to that system No modifications or alterations are permitted...

Страница 5: ...above the other Tie back rails must be 6 2 4m from any parallel fall hazard edge Each system comes with a unique layout drawing with details specific to that system No modifications or alterations ar...

Страница 6: ...he same direction Build both ladder assemblies to the required height shown on the system specific drawing Torque set screws to 25 ft lbs If torque wrench is not available tighten set screw until it c...

Страница 7: ...ghtened to approximately 18 ft lbs If torque wrench is not available tighten set screw until it contacts pipe then tighten one more full revolution Plug open top with RGF Cap Top of top rail should be...

Страница 8: ...hten set screw until it contacts pipe then tighten one more full revolution Plug open top with RGF Cap Two baseplates to be used at each diagonal brace Refer to unique layout drawing for your system f...

Страница 9: ...lbs If torque wrench is not available tighten set screw until it contacts pipe then tighten one more full revolution Plug open top with RG Cap 6 rails between posts for tie back counterweights Top of...

Страница 10: ...late required to be secured against post Torque to 25 ft lbs If torque wrench is not available tighten set screw until it contacts pipe then tighten 1 5 more revolutions Post Base Connection Diagonal...

Страница 11: ...of any electrical lines DO NOT use if any component is found defective or damaged DO NOT attach banners signs or equipment to rail DO NOT apply an excess force to the top rail which could cause tippin...

Страница 12: ...ntario N0B 1E0 1 800 977 2005 info liftsafeinspections com www fallsafetysolutions com C N I N O I T C E T O R P L L A F LIFTSAFE Factory Supply 8001 Tower Point Drive Charlotte NC 28227 1 888 242 304...