background image

           

   Products by Nasco

CR

i

S

is

Manikins

  LF03953U – Complete 

CR

i

S

is

  LF03955U – Deluxe 

CR

i

S

is

  LF03956U – Deluxe Plus 

CR

i

S

is

  LF03965U – 

CR

i

S

is

™ 

Auscultation

  LF03966U – 

CR

i

S

is

™ 

Auscultation w/Interactive ECG

  LF03968U – Deluxe Plus 

CR

i

S

is

™ 

Auscultation

INSTRUCTION MANUAL

NOTE: These products contain dry natural rubber.

Содержание CRiSis LF03953U

Страница 1: ...plete CRiSis LF03955U Deluxe CRiSis LF03956U Deluxe Plus CRiSis LF03965U CRiSis Auscultation LF03966U CRiSis Auscultation w Interactive ECG LF03968U Deluxe Plus CRiSis Auscultation INSTRUCTION MANUAL...

Страница 2: ...defects in material and workmanship for a period of three years from the date of purchase Nasco will repair any defect reported within three years of the date of purchase at no charge Products found t...

Страница 3: ...ult 27 Defibrillation Training Pediatric 28 External Pacer Training Pediatric 28 Procedure C Auscultation Introduction 29 Instructions for Use 29 Supplies Replacement Parts for Auscultation 29 Introdu...

Страница 4: ...MODEL Pages 5 10 display the Adult CRiSis family of simulators Identify your Life form Adult CRiSis Manikins model and refer to the Operation Section pertaining to your model This guide has been care...

Страница 5: ...m Blood Pressure Arm Electronic Blood Pressure Control Unit Defibrillation Chest Skin Pump Spray Lubricant 3 cc Syringe with Needle 12 cc Syringe with Needle Two IV Bags Three Pinch Clamps Two Small T...

Страница 6: ...e Arm Electronic Blood Pressure Control Unit Defibrillation Chest Skin Pump Spray Lubricant 3 cc Syringe with Needle 12 cc Syringe with Needle Two IV Bags Three Pinch Clamps Two Small Towels Butterfly...

Страница 7: ...lation Chest Skin Pump Spray Lubricant 3 cc Syringe with Needle 12 cc Syringe with Needle Two IV Bags Three Pinch Clamps Two Small Towels Butterfly Infusion Set Synthetic Blood Sphygmomanometer Batter...

Страница 8: ...e Control Unit Defibrillation Chest Skin Pump Spray Lubricant 3 cc Syringe with Needle 12 cc Syringe with Needle Two IV Bags Three Pinch Clamps Two Small Towels Butterfly Infusion Set Synthetic Blood...

Страница 9: ...re Control Unit Defibrillation Chest Skin Pump Spray Lubricant 3 cc Syringe with Needle 12 cc Syringe with Needle Two IV Bags Three Pinch Clamps Two Small Towels Butterfly Infusion Set Synthetic Blood...

Страница 10: ...pray Lubricant 3 cc Syringe with Needle 12 cc Syringe with Needle Two IV Bags Three Pinch Clamps Two Small Towels Butterfly Infusion Set Synthetic Blood Sphygmomanometer Batteries Included Electronic...

Страница 11: ...se see Using the Combitube Suction techniques and proper cuff inflation can also be per formed and evaluated Lubricating the Airway Trainer Head Lubricate both the simulator and supplies being used wi...

Страница 12: ...the upper compression plate See figure 5 Figure 5 4 Place the lung bags through the hole in the center of the upper compression plate so they rest on top of the plate See figure 6 Figure 6 5 Place th...

Страница 13: ...disinfect repeat the standard cleaning procedure but this time use a bleach solution as specified by the Centers for Disease Control instead of soapy water Fill the system with the solution until it...

Страница 14: ...oner The Skin and Vein Kits are available through Nasco see page 9 for list of supplies Internal Structure Internally the vascular structure rub ber tubing begins at the shoulder and continues under t...

Страница 15: ...be aspirated once the vein is prop erly punctured 8 Small diameter needles 20 to 25 gauge should be used Figure 14 B Preparing the Arm for Intravenous Infusions 1 Close the clamp at the end of IV bag...

Страница 16: ...desirable rate with clamp With this arrangement the IV bag B when full may be easily switched with A NOTE always regulate flow of blood from the raised bag and open the other clamp D Intramuscular In...

Страница 17: ...ulated to be compatible with the self sealing veins and plastics used in manufacturing the arm 2 NEVER use synthetic blood for intramuscular injection 3 DO NOT use dull or burred needles as these will...

Страница 18: ...e After the bat teries have been properly installed reassemble the Blood Pressure Simulator by simply reversing the dis assembly procedures Place the unit face up on the work surface and turn it on by...

Страница 19: ...ng Yourself with the Nasco Life form Blood Pressure Simulator Control Panel Under the display window are three buttons Menu Gap and Calibrate See figure 20 The systolic pres sure is set by pressing th...

Страница 20: ...he trainee can become familiar with this phenomenon Pressing the Gap key simply turns the gap function off or on When the key is pressed a message will briefly appear that the ausculatory gap is enabl...

Страница 21: ...e as it would normally be performed except that the stethoscope need not be used Instead listen to the sounds as they emanate from the speaker amplifier noting the differences in the Korotkoff phases...

Страница 22: ...key to change the diastolic window See figure 28 With the arrow down key set the correction to 2 Press the Menu key again and the message CALIBRATION COMPLETE will appear The main menu window will be...

Страница 23: ...ctors it will be necessary to purchase the corresponding adapt ers from Nasco To order please see Supplies Replacement Parts on page 15 Figure 33 Nasco Life form Defibrillation Chest Skin About the Si...

Страница 24: ...connections on the patient simulators one or more may be disconnected 2 Check to make sure your patient simulator is plugged in and working properly Problem ECG wave is inverted Solution Recheck the p...

Страница 25: ...utomatically from one rhythm running rhythm to another rhythm waiting rhythm when a defib discharge is sensed If defibrillating into Nasco manikin set defib energy to 2J or more If defibrillating dire...

Страница 26: ...nitor defibrillator Observe that NSR at 72 bpm is displayed Using Simulator without Defib Manikin 1 Connect monitor s ECG cable to simulator s ECG snaps See Figure 1 2 Using your pad adapters or pad a...

Страница 27: ...VT alternates with NSR then remains in SVT SVT rate 216 S TACH Sinus Tachycardia Rate 120 NSR Normal Sinus Rhythm Rate 72 ASYS Asystole SINUS PVC Sinus Rhythm with PVCs Sinus rate 72 FOR EXTERNAL PACE...

Страница 28: ...er 2 1 Ventricular rate 150 SVT Supraventricular Tachycardia Inverted P follows QRS Rate 240 S TACH Sinus Tachycardia Rate 165 NSR Normal Sinus Rhythm Rate 90 ASYS Asystole SINUS PVC Sinus Rhythm with...

Страница 29: ...he scroll button After the condition is selected press the enter button to activate The remote control can be programmed to these heart conditions 01 Normal 02 Aortic regurgitation 03 Pulmonary stenos...

Страница 30: ...l is displayed separately while averages are stored in the memory Designed to automatically switch between the compression and ven tilation modes depending on which one is being applied Electronic Mon...

Страница 31: ...every time the compres sion depth of 1 00 inch is reached It will turn off when it drops below this depth or if it exceeds 1 50 inches TROUBLE SHOOTING The red placement light is continu ously on ind...

Страница 32: ...on is pushed Upon pushing the stop button the unit will calculate and display the average depth of all com pressions from the start of the present cycle Any compressions made after the stop button is...

Страница 33: ...duration in sec onds of the last ventilation The unit will continue this display mode until the mode is changed or the stop but ton is pushed Upon pushing the stop button the unit will calculate and d...

Страница 34: ...t shows 1 Time scale 1 8 1 second 2 Axis for compression waveforms start at the center and goes left 3 Axis for ventilation waveforms start at the center and goes right 4 1 0 limit line for compressio...

Страница 35: ...towards the front of the printer See figure 10 5 While keeping paper taut position the paper within the guides of the printer and re install the platen so that the gears of the platen engage with the...

Страница 36: ...36 Procedure F Troubleshooting Information is on pages 31 33 Supplies Replacement Parts for Printer LF03451U Thermal Printer Paper...

Страница 37: ...lus CRiSis Auscultation Manikin LF03968U CRiSis Torso s No Heart and Lung Sounds CRiSis Torso Manikin LF03957U Deluxe CRiSis Torso Manikin LF03958U Nasco CRiSis Manikins E l e c t r o n i c M o n i t...

Страница 38: ...PR Dog LF01162U Venatech IV Trainer LF01174U NG Tube Trach Skills LF01184U Venatech IM Sub Q LF01193U Special Needs Baby LF03000U CPARLENE Series LF03601U Adult Airway Management Trainer with Stand LF...

Отзывы: