background image

69-RNC-Install 012616

Installation Guide 

RNC Series 

Setting a new standard for

energy efficient, clean air homes

511 McCormick Blvd

London, Ontario Canada N5W 4C8 

519.457.1904

General Info / Tech Support

1.855.247.4200

  

www.lifebreath.com

Содержание RNC series

Страница 1: ...2616 Installation Guide RNC Series Setting a new standard for energy efficient clean air homes 511 McCormick Blvd London Ontario Canada N5W 4C8 519 457 1904 General Info Tech Support 1 855 247 4200 ww...

Страница 2: ...hart RNC205 Model 28 Troubleshooting 30 Location Installation Notes Install the unit in a heated space that provides clearance for service access A typical location is in either a mechanical room or a...

Страница 3: ...t with ground The use of an extension cord with this unit is not recommended If the installation requires further wiring have a licensed electrician make all of the electrical connections The recommen...

Страница 4: ...led on the Stale Air to Outside Collar 3 min recommended Forced Air Furnace Cool Air Return 40 in 1 m Minimum Dampers for balancing airflows Outdoors Return Air 3 ft min recommended Backdraft Damper L...

Страница 5: ...o Outside Collar Forced Air Furnace Cool Air Return Dampers for balancing airflows Outdoors 3 ft min recommended Backdraft Damper Leaf Hinge Installed Vertically Recommended Applications such as green...

Страница 6: ...mper with the leaf hinge vertical The damper is installed on the Stale Air to Outside Collar Outdoors Dampers for balancing airflows Stale air from various parts of home i e bathrooms if required kitc...

Страница 7: ...rom right to left to right and front to back Adjust the unit up by pulling down vertically on the hand loops while lifting up on the bottom of the cabinet Step 5 Fold the hand loops in excess strap an...

Страница 8: ...nnection is complete This creates a water seal which will prevent odours from being drawn up the hose and into the fresh air supply of the HRV Caution Hard Pipe Plumbing To Drain Pre Punched Holes 2 D...

Страница 9: ...he unit to balance the amount of stale air being exhausted with the amount of fresh air being brought into the house Refer to airflow balancing section The Lifebreath Kitchen Grille includes a removab...

Страница 10: ...have access to attach the retaining ring Available size 6 in Connect to HRV ducting Ceiling Fitting Retaining ring Flush mount the lip of the ceiling fitting to ceiling TechGrille Ceiling Quick Mount...

Страница 11: ...tly and be as short as possible to minimize air flow restrictions Twisting or folding the duct will severely restrict airflow Hard rigid ducting which has been sealed and insulated should be used for...

Страница 12: ...near a gas meter electric meter or a walkway where fog or ice could create a hazard EXHAUST INSIDE CORNER INTAKE 18 in 460 mm min 3 ft 1 m recommended min 3 ft 1 m recommended min OUTSIDE CORNER 6 ft...

Страница 13: ...the back plate from the wall and mark the center hole for the wires in the middle of the screw holes Refer to Figure D E or F for dimensions Drill two 1 8 in holes for the screws and wall anchors Fig...

Страница 14: ...air handler furnace blower system Building codes in some areas require fully off functionality Check with your local building authority before modifying the unit to standby off Unintentional operatio...

Страница 15: ...t and right buttons simultaneously on the main wall control and RESET buttons The screen will go blank and the wireless symbol will appear flashing on the bottom right of the display This indicates th...

Страница 16: ...ontrols Press the left and right buttons simultaneously on the main wall control and either or buttons depending on the main control The bottom row of 3 LED s will begin flashing This indicates that t...

Страница 17: ...h speed using screw driver adjust dial clockwise for the Supply side until the desired High fan speed is achieved 3 To adjust the Exhaust fan for High speed using screw driver adjust dial clockwise fo...

Страница 18: ...nnect Yellow Red Green wires on side of 99 DET01 to the terminal block on unit using 3 wire 20 gauge min 100 ft length max Operating the Timer Press and release theSelect Button to activate a 20 40 or...

Страница 19: ...Filter Note Front clearance of 25 in 635 mm is recommended for servicing unit All ducts use 5 in 125 mm oval collars balancing dampers are located on all collars 16 1 2 in 419 mm 28 5 8 in 727 mm Bot...

Страница 20: ...l walls of the building Once inside the external walls moist air may condense in cold weather and degrade structural components or cause locks to freeze Continuous excessive negative pressure may have...

Страница 21: ...k to the collar take note where screws are located Screws should be located no further than 1 2 in from outside edge of collar so as not to impede operation of the damper 1 2 in Push and turn with slo...

Страница 22: ...ube with the tip facing towards the air stream in the stale air from Building air stream Move the pitot tube around in the duct facing toward the airflow and take an average reading Record the reading...

Страница 23: ...ions Seal the fresh air balancing ports with tape see illustrations for port locations Record your reading Step 6 Insert the 2 rubber fittings from the gauge to the fresh air balancing ports see illus...

Страница 24: ...13 153 140 0 370 93 139 120 0 680 170 152 0 460 115 151 138 0 380 95 137 117 0 690 173 149 0 470 118 149 135 0 390 98 135 115 0 700 175 147 0 480 120 147 133 0 400 100 133 113 0 710 178 144 0 490 123...

Страница 25: ...165 80 54 0 970 243 113 79 0 750 188 97 72 0 670 168 78 52 0 980 246 111 76 0 760 190 95 69 0 680 170 76 50 0 990 248 108 74 0 770 193 93 67 0 690 173 74 48 1 000 251 105 71 0 780 195 91 65 0 700 175...

Страница 26: ...52 99 0 070 18 53 101 0 070 18 57 98 0 070 18 55 104 0 075 19 56 105 0 075 19 60 102 0 075 19 58 108 0 080 20 59 109 0 080 20 62 106 0 080 20 61 113 0 085 21 62 113 0 085 21 65 110 0 085 21 64 117 0...

Страница 27: ...0 250 63 145 0 255 64 136 0 255 64 143 0 255 64 148 0 260 65 138 0 260 65 145 0 260 65 150 0 265 66 139 0 265 66 147 0 265 66 152 0 270 68 141 0 270 68 149 0 270 68 155 0 275 69 143 0 275 69 151 0 27...

Страница 28: ...160 0 410 103 126 145 0 620 155 180 198 0 520 130 139 157 0 420 105 123 142 0 630 158 177 195 0 530 133 136 154 0 430 108 120 139 0 640 160 174 193 0 540 135 133 151 0 440 110 117 136 0 650 163 171 1...

Страница 29: ...0 223 54 68 0 790 198 42 54 1 000 250 83 105 0 900 225 53 66 0 800 200 40 53 1 010 253 81 103 0 910 228 51 65 0 810 203 39 51 1 020 255 79 101 0 920 230 49 63 0 820 205 38 50 1 030 258 77 99 0 930 233...

Страница 30: ...coming into the home from an unvented or unheated crawl space Moisture is remaining in the wash room and kitchen areas Condensation seems to form in the spring and fall HRV is set at too low a speed S...

Страница 31: ...avoir de la condensation au printemps et l automne la vitesse pr vue pour le VRC est trop basse r glez le d shumidistat plus bas couvrez la piscine et le hot tub quand vous ne vous en servez pas vite...

Страница 32: ...70 193 44 58 0 980 245 87 110 0 880 220 56 70 0 780 195 43 56 0 990 248 85 108 0 890 223 54 68 0 790 198 42 54 1 000 250 83 105 0 900 225 53 66 0 800 200 40 53 1 010 253 81 103 0 910 228 51 65 0 810 2...

Страница 33: ...51 0 440 110 117 136 0 650 163 171 190 0 550 138 130 148 0 450 113 114 133 0 660 165 168 188 0 560 140 127 145 0 460 115 111 130 0 670 168 165 185 0 570 143 125 143 0 470 118 108 127 0 680 170 162 182...

Страница 34: ...59 135 0 235 59 138 0 240 60 131 202 0 240 60 137 0 240 60 141 0 245 61 132 0 245 61 139 0 245 61 143 0 250 63 134 0 250 63 141 0 250 63 145 0 255 64 136 0 255 64 143 0 255 64 148 0 260 65 138 0 260...

Страница 35: ...109 0 080 20 62 106 0 080 20 61 113 0 085 21 62 113 0 085 21 65 110 0 085 21 64 117 0 090 23 65 117 0 090 23 67 114 0 090 23 67 122 0 095 24 68 120 0 095 24 70 118 0 095 24 70 127 0 100 25 71 124 0 10...

Страница 36: ...119 84 0 730 183 100 76 0 650 163 82 57 0 960 241 116 81 0 740 185 99 74 0 660 165 80 54 0 970 243 113 79 0 750 188 97 72 0 670 168 78 52 0 980 246 111 76 0 760 190 95 69 0 680 170 76 50 0 990 248 10...

Страница 37: ...120 147 133 0 400 100 133 113 0 710 178 144 0 490 123 145 131 0 410 103 131 111 0 720 180 142 0 500 125 144 129 0 420 105 129 108 0 730 183 139 0 510 128 142 126 0 430 108 127 106 0 740 185 137 0 520...

Страница 38: ...soit bien ajust et suffisamment serr Le tube ne doit pas d passer au del du raccord en caoutchouc tape 3 Ouvrez la porte du VRC Enlevez les bouchons des quatre orifices en les poussant soigneusement...

Страница 39: ...pour r duire le d bit du conduit o la v locit est la plus haute R p tez les tapes 2 et 3 jusqu ce que vous obteniez des lectures identiques dans les deux conduits tape 4 b Une fois l quilibrage termin...

Страница 40: ...ce transversale de quelques conduits ronds souvent utilis s 0 087 pour un conduit de 4 po 0 139 pour un conduit de 5 po 0 196 pour un conduit de 6 po 0 267 pour un conduit de 7 po Appareils munis de c...

Страница 41: ...rous de serrures Une pression n gative excessive ininterrompue pourrait avoir plusieurs effets secondaires ind sirables Dans certaines r gions il est possible que des gaz provenant du sol tels que le...

Страница 42: ...r neuf vers l int rieur Air vici vers l ext rieur Air vici de l int rieur Air neuf de l ext rieur Air neuf vers l int rieur Air vici vers l ext rieur 17 1 4 po 438 mm 22 3 4 po 578 mm 14 po 356 mm Dev...

Страница 43: ...de l appareil au moyen d un c ble d un calibre minimal 3 20 d une longueur maxi de 100 pi 30 m Utilisation Enfoncez et rel chez le bouton s lecteur pour commencer un cycle prioritaire de 20 40 ou 60...

Страница 44: ...on ou d vacuation une HAUTE vitesse voyant jaune qui reste allum 1 Enfoncez et retenez le bouton de r glage jusqu ce que le voyant jaune reste allum 2 Pour r gler le ventilateur d aspiration une haute...

Страница 45: ...pairage Pour apparier des r p teurs RX02 suppl mentaires avec la m me commande murale ou si le pairage a chou r p tez les tapes 1 5 Une fois appari s les r p teurs RX02 peuvent tre d plac s et branch...

Страница 46: ...ncipale La rang e inf rieure des 3 t moins DEL commence clignoter Cela indique que la commande principale se trouve alors en mode de pairage figure E 4 Lors du pairage gardez la minuterie dans un rayo...

Страница 47: ...rche chaque fois que le VRC fait son travail de ventilation Quand il s agit d une installation simplifi e m thode reprise reprise le VRC doit tre synchronis avec l appareil de chauffage fournaise ou a...

Страница 48: ...ri re et marquez le trou pour le fil au centre entre les trous de vis Reportez vous la figure D E ou F pour les dimensions 6 Percez 2 trous de 1 8 po pour les vis et chevilles figure D E ou F Dans le...

Страница 49: ...devrait s parer les capuchons d admission et d vacuation Ils doivent tre au moins 18 pouces 460 mm au dessus du sol ou au dessus de la profondeur pr vue pour l accumulation de neige en hiver Ils doive...

Страница 50: ...ation de l air la gaine flexible isol e qui raccorde les deux capuchons anti intemp ries ext rieurs au VRC devrait tre bien tir e et aussi courte que possible Quand le conduit est tortill ou pli la ci...

Страница 51: ...ntage rapide sur le montant TechGrille Rev tement de 1 2 po Raccord montage rapide Coude pour sommet de canalisation Pi ce N 99 WF6 Utilisez ce raccord avant la pose du rev tement mural int rieur Ce r...

Страница 52: ...ini re Des registres d quilibrage fournis sur place devraient tre pos s l ext rieur du ventilateur pour quilibrer l vacuation d air vici de la maison et l adduction d air neuf dans la maison Voyez la...

Страница 53: ...Attache Zip Bac de drainage Bac de drainage Plomberie boyau d coulement Trous perc s d avance 2 Goulotte d gouttement Plomberie tuyau rigide Trous perc s d avance 2 Bac de drainage Bac de drainage Gou...

Страница 54: ...rnies travers les oeillets des bandes de suspension et fixez les aux solives Figure A tape 2 D vissez les quatre 4 vis m taux qui se trouvent sur la partie sup rieure de l appareil Attachez les croche...

Страница 55: ...cheuse aux vents des salles de bains etc Tous les appareils vacuation devraient obtenir leur propre air d appoint car il ne s agit pas l d une fonction pr vue pour le VRC La configuration des conduit...

Страница 56: ...e VRC alors que l appareil de chauffage ou de traitement de l air est en marche et que le VRC est en attente Standby arr t OFF ou son mode de recirculation Attention Avertissement Le VRC doit tre quil...

Страница 57: ...lation Le VRC doit tre quilibr L appareil devrait tre quilibr haute vitesse alors que la soufflante de l appareil de chauffage fournaise est en marche ON Il est essentiel que la soufflante de l appare...

Страница 58: ...cordon prolongateur avec cet appareil Si vous avez besoin de c blage additionnel il faut confier un lectricien comp tent le soin de faire toutes les connexions lectriques On recommande d employer un...

Страница 59: ...D pannage 30 Emplacement Remarques concernant l installation Installez l appareil dans un endroit chauff o il y aura suffisamment d espace libre afin d assurer un acc s facile pour les travaux d entre...

Страница 60: ...NC Install 012616 La nouvelle r f rence en mati re de rendement nerg tique et d air pur pour la maison 511 boulevard McCormick London Ontario Canada N5W 4C8 519 457 1904 Information g n rale support t...

Отзывы: