PAGE # 14
Call 1-877-744-3649 for assistance or visit us at www.phoenixinno.com
LEAK TEST
1.
All factory-made connections of the hose and regulator have been thoroughly tested to ensure no gas leaks are present.
However, through shipping and handling, certain gas connections may have loosened. As a safety precaution:
a. Check all connections for gas leaks before using the appliance
b. Check for gas leaks at the LP cylinder valve after each time the cylinder is replaced or at the
NG supply valve any time the fitting is reconnected.
c. Do not smoke while checking for gas leaks or anytime you are in the vicinity of the appliance.
d. Never test for gas leaks with a lit match or open flame.
e. Always test for gas leaks outdoors in a well-ventilated area.
2.
Even if this appliance was assembled for you by someone else,
be sure to check for gas leaks.
TO TEST FOR GAS LEAKS:
1.
Extinguish any open flame or cigarettes in the area.
2.
Be sure that the LP gas cylinder service valve and all burner control valves are closed (“OFF”).
3.
Connect a full LP gas cylinder to the appliance.
4.
In a bowl, create a soap solution of 1 part water with 1 part liquid detergent.
5.
Open the LP gas cylinder service valve slowly.
6.
Brush the soap solution over each connection point (including connections to side and rotisserie burners if applicable).
7.
A gas leak will be identified by expanding bubbles originating from the point of the leak.
8.
If a gas leak is detected at any connection, close the LP gas cylinder service valve, tighten the leaky connection(s) and re-check (steps 5-8).
9.
If the gas leak persists, do not operate the appliance. Contact your local gas grill dealer for assistance.
Release Sleeve
Retract Sleeve
Plug
Release Sleeve
NATURAL GAS SUPPLY CONNECTION
(FOR NG MODELS ONLY)
1.
This appliance is for use with natural gas only. The conversion to or attempted use of liquid propane (LP) gas in this appliance is dangerous
and will void your warranty.
TO CONNECT:
1.
Push back the sleeve on the socket as shown.
(See Fig. 15).
2.
Insert plug and release the sleeve
(See Fig. 16).
3.
Push the plug until Sleeve snaps forward to lock the plug in the socket.
WARNING:
Always conduct leak test before lighting the grill.
TO DISCONNECT:
1.
Retract sleeve and pull the plug out.
Bubbles = Leak
Fig. 15
Fig. 16
Fig. 17
For Models:
PH503SBB
PH503SBBN
✓
✓