Error 75
Error Message Displayed to user
•
E75
•
doStartWorkflow-Up Failure
Condition
System unexpectedly timed out retrieving base data at power-up. Retry to power up first to see if there was a
temporary failure. If problem persists, then check other causes.
Cause
• Comm cables from base to console
• Low battery
• Intermittent / low power
• Ensure that latest software is installed. Download the latest software
Remedy
• Cycle power
• Check and reseat console to base cables, wiggle cables - watch for LED flickers that may indicate loose connections
• Check base boards for signs of life. Ensure the following LED's are lit:
• System Interface Board (1,2,4,5, 14, and 16)
• Motor Drive Board (100, 101, 200, 400, 500, 501, 502, 601)
• AC and DSP (1, 2, 6, 7, 8)
• PMC (1, 2, 6, 7, 8, 11)
• Check battery voltage is above 6V
Page 100 of 153