heat  and  combustion 

products 

rise 

to 

the 

ceiling 

and 

spread 

horizontally.     

Mounting  the  alarm  on 

the ceiling in the center 

of  the  room  places  it 

closest  to  all  points 

in  the  room.    When 

mounting a detector on 

the  ceiling,  locate  it  at 

a minimum of 4 inches 

(10  cm)  from  the  side 

wall  (see  Figure  3).    If 

installing the detector on the wall, use an inside wall with 

the top edge of the device at a minimum of 4 inches (10 cm) 

and a maximum of 12 inches (30.5 cm) below the ceiling 

(see Figure 4).

SLOPED  CEILING  INSTALLATION: 

According  to  the 

National Fire Protection Association (NFPA) Fire Code 72, 

one should install smoke detectors on sloped, peaked or 

cathedral ceilings at or within 3 feet (0.9 m) of the highest 

point (measured horizontally).  Do not install the Smoke/

CO  detector  in  the  peaks  of  vaulted  ceilings,  “A”  frame 

ceilings, or gabled roofs (see Figure 4).  Smoke detectors 

in rooms with ceiling slopes greater than 1 to 8 feet (0.3 to 

2.4 m) horizontally should be located on the high side of the 

room.  A row of detectors should 

be  spaced  and  located  with  3 

feet (0.9m) of the peak of the 

ceiling  measured  horizontally. 

REMOVING  THE  BRACKET:  

Remove  the  bracket  from 

the  back  of  the  Smoke/CO 

detector  by  holding  the  rim 

of  the  bracket  and  twisting  it 

counter-clockwise  (to  the  left) 

as shown here.  Once removed, 

proceed to install the batteries.   

The Smoke/CO detector 

requires  three  (3)  AA 

Energizer  L91  lithium 

batteries.    Open  the 

battery covers and insert 

a battery into each of the 

three 

compartments.  

The  battery  polarity 

markings  on  the  cover 

and  inside  of  each 

battery 

compartment 

must be adhered to.  The 

battery  compartments 

are  fitted  with  a  red 

latch  that  will  prevent 

the detector from locking 

onto the bracket if there are no batteries inside.  All three 

batteries must be properly installed  and in good condition 

for the unit to operate.  Removal of any of the batteries 

will render the detector inoperative.  Replacement batteries 

may  be  purchased  at  your  local  retailer.    Only  use  the 

batteries specified.

MOUNTING  THE  BRACKET: 

    The  detector  must  be 

mounted  on  a  wall  or  ceiling  with  its  bracket.    It  is  not 

designed for use as a tabletop device. Hold the bracket

against the selected installation location (wall or ceiling) 

and mark the center of the holes with a pencil.  Drill a hole 

through each pencil mark and fasten the bracket to mounting  

surface  with  two  (2)  screws.    Once  mounted,  carefully 

align the detector with the bracket and rotate it clockwise 

(to the right) until the device is locked in place.  Gently pull 

the detector outward to verify that it is securely attached.   

TESTING: 

 Test both sensors with the Monitoring Center 

once installation is complete.  Press and hold down each 

test button (separately) until the built-in siren sounds and 

the  HELP  PERS  base  unit  begins  to  enunciate  that  an 

alarm has been activated.  Wait for a Life Alert Operator 

to respond and confirm a successful test.  Make sure to 

conduct  a  separate  test  for  each  sensor.    The  Smoke/

CO  detector  must  be  tested  regularly  to  ensure  that 

the  batteries  and  alarm  circuits  are  in  good  operating 

condition.  The test buttons for the Smoke and CO sensors 

may also be used to enroll sensors.

WARNING:

 The tests buttons are the only way 

to  properly  test  the  smoke  and  CO  sensors. 

Never use smoke or vehicle exhaust as they may cause 

permanent damage and void your warranty. 

To keep your Smoke/CO detector in good working order, 

please follow these simple steps.  Verify alarm siren, LED 

lights, and battery operation by pushing the test buttons at 

least once a week.  Remove the device from the mounting 

bracket and vacuum the detector cover and vents with a 

soft brush attachment once a month to remove dust and 

dirt.    Reinstall  immediately  after  cleaning  and  then  test 

using the tests button.  Never attempt to disassemble the 

unit  or  clean  inside  of  it  as  this  will  void  your  warranty.  

Never use detergents or solvents to clean the unit.  When 

household cleaning supplies or similar contaminates are 

used,  the  area  must  be  well  ventilated.    The  following 

substances can damage the sensors and may cause false 

readings: methane, propane, isobutene, isopropanol, ethyl 

acetate, hydrogen sulfide, sulfide dioxides, alcohol base 

products, paints, thinner, solvents, adhesives, hair spray, 

after shave, perfume, and some cleaning agents.  Do not 

paint  the  device.    Paint  will  seal  the  vents  and  interfere 

with its ability to detect smoke and CO.  Move the detector 

prior  to  performing  any  of  the  following:  staining  or 

stripping wood floors or furniture, painting, wall papering, 

using adhesives.  Store the detector in a plastic bag during 

any of the above projects to help protect the sensors from

HELP PERS  

SUPERVISED

WIRELESS COMBINATION

SMOKE/CO DETECTOR

INSTALLATION 

INSTRUCTIONS

MODEL NO. LASD-01

®

This  installation  instruction  guide  will  introduce  you  to  the 

basic features, operations, and safety considerations of the 

Life Alert HELP PERS combination Smoke/Carbon Monoxide 

(CO)  detector.    Please  take  the  time  to  thoroughly  read 

this guide and save it for future reference.  The detector is 

designed  to  automatically  and  independently  sense  both 

smoke  (not  flame)  and  CO  gas  in  an  ordinary  residential 

environment.    It  provides  an  early  warning  of  developing 

smoke  and  CO  events  by  sounding  a  built-in  85  decibel 

alarm siren and transmitting an alarm signal to the Life Alert 

Monitoring Center via the HELP PERS base unit.  

CAUTION!! 

This  device  will  only  indicate  the  presence 

of smoke and CO gas at the sensor.  Smoke and CO gas 

may  be  present  in  other  areas  of  the  residence.  

Effective  pre-warning  of  smoke  and  CO  events  is 

only  possible  if  the  detector  is  located,  installed 

and maintained as described here in this guide.  If you have 

any questions about this device, please contact the Life Alert 

Technical  Service  Department  at  1-800-451-7858.    16027 

Ventura Blvd. Suite 400 Encino CA 91436, U.S.A
The  Smoke/CO  detector  will  operate  and  alert  you  to  the 

following conditions in the manner described here: 

FEATURES
SMOKE  ALARM:

    Utilizing  photoelectric  technology,  the 

smoke sensor monitors the air for products of combustion

that are produced when something is burning or smoldering.  

When smoke particles in the smoke sensor reach a specified 

concentration, the alarm siren will sound.  The alarm pattern 

is three (3) short alarm sirens with three (3) corresponding 

flashes  of  the  red  LED  light.    This  pattern  will  repeat  until 

the  smoke  event  is  eliminated.   The  smoke  alarm  will  take 

precedence  when  both  smoke  and  CO  are  present.    For 

increased  protection,  Life  Alert  recommends  that  both 

ionization  and  photoelectric  detectors  be  installed  in  the 

residence.

CO ALARM:

    Utilizing  electrochemical  technology,  the  CO 

sensor monitors the air for the presence of carbon monoxide.  

When there are high levels of CO present, or low levels of 

CO present over a longer period of time, the alarm siren will 

sound.  The alarm pattern is four (4) long alarm sirens with 

four  (4)  corresponding  flashes  of  the  red  LED  light.    This 

pattern will repeat until the CO event is eliminated.  The CO 

sensor is designed to detect carbon monoxide gas from ANY 

source  of  combustion.   

IT IS NOT DESIGNED TO DETECT 

ANY OTHER GAS.
TEST BUTTONS: 

  To conduct a local test, push the two test 

buttons  at  the  same  time  to  verify  proper  Smoke  and  CO 

sensors operation. If both test buttons are pressed, the alarm 

pattern is one (1) short alarm siren with one (1) corresponding 

steady flash of the red LED light. 

LOW  BATTERY:

      The  device  is  powered  by  three  (3) AA 

Energizer  L91  lithium  batteries.  When  the  batteries  are  low 

and need to be replaced, the device will chirp once and the 

amber  LED  light  will  flash  once  every  fifty  (50)  seconds. 

The pattern will repeat until the batteries are removed (and 

replaced) or the batteries cease functioning.

SMOKE TROUBLE: 

 When there is a trouble issue with the 

Smoke sensor, the device will chirp three (3) times and the 

amber LED light will flash once every fifty (50) seconds.

SMOKE LOW SENSITIVITY: 

 When there is a low sensitivity 

issue  with  the  Smoke  sensor,  the  device  will  chirp  two  (2) 

times and the amber LED light will flash once every fifty (50) 

seconds.

CO  TROUBLE: 

  When  there  is  a  trouble  issue  with  the 

CO  sensor,  the  device  will  chirp  once  and  the  amber 

LED  light  will  flash  two  (2)  times  every  fifty  (50)  seconds. 

 

END OF PRODUCT LIFE:  

 After five (5) years of cumulative 

use, the device will chirp once and the amber LED light will 

flash  four  (4)  times  every  fifty  (50)  seconds.  This  indicates 

that the device must be replaced immediately as it may not 

be able to detect CO in this condition. Please call the Life Alert 

Technical Service Department at 1-800-451-7858 for further 

assistance.

WHERE  TO  INSTALL: 

  Before  installing  your  Smoke/CO 

detector, it is important to choose the best locations in your 

home.    Placement  will  affect  how  well  the  device  performs 

and how well residents hear the alarm siren if it sounds.  For 

maximum  protection,  Life  Alert  recommends  a  Smoke/CO 

detector be installed on each level of a multi-level home, 

including  every  bedroom,  hallways,  finished  attics  and 

basements.    Install  a  detector  in  every  room  where 

someone sleeps with the door closed.  A closed door may 

prevent a detector not located in that room from waking the 

occupant.  For bedrooms, hallways, or large rooms greater 

than 30 feet (9.1 m) in length, install detectors at both ends 

of  the  room  or  hallway.    For  additional  protection,  place 

additional  Smoke/CO  detectors  between  5  and  20  feet 

from  potential  sources  of  CO,  such  as  a  furnace,  water 

heater or fireplace.   

 If you only have one detector, ensure it is placed in the 

hallway outside of the  main sleeping area, or in the main  

bedroom.    Verify  that  the  detector  can  be  heard  in  all 

sleeping areas.  

Do not install the Smoke/CO detector in garages, kitchens, 

furnace rooms, fireplaces, bathrooms, or unfinished attics.  

Keep  the  device  at  least  5  feet  (1.5  m)  away  from  any 

fuel-burning equipment.  Keep the device at least 3 feet 

(0.9  m)  away  from  the  following:  a  door  to  a  kitchen  or 

bathroom (that contains a tub or shower), air conditioners 

or  forced  air  supply  ducts  used  for  heating  or  cooling, 

ceiling or whole house ventilating fans, or other high air 

flow areas.  Keep the detector away from drapes or other 

objects that may block airflow to the sensors.  Do not place 

the device in the direct sunlight or near doors and windows 

that open up to the outside.  Install the detector at least 1 

foot (0.3 m) away from fluorescent lights.  Do not install in 

areas  where  the  temperature  is  colder  than  40  degrees 

Fahrenheit  (4.4  Celsius)  or  hotter  than  100  degrees 

Fahrenheit  (37.8  Celsius)  as  extreme  temperature  will 

affect  the  sensitivity  of  the  Smoke/CO  detector.    Do  not 

install in areas where the relative humidity is greater than 

85%.  Avoid excessively dirty, dusty, or greasy areas.  Dirt, 

dust, grease, or household chemicals can contaminate the 

device’s sensors, causing it to not operate properly.  Make 

sure to keep the detector away from any insect infested 

areas.

CEILING OR WALL INSTALLATION: 

Ceiling mounting is 

preferred in an ordinary residential environment.  Smoke, 

Figure 4.  

 Recommended Locations on Sloped Ceilings

Figure 6.  

 Detector Rear Side and 

Proper Battery Placement

Figure 8. 

 General View of Smoke/CO Detector

Figure 3.  

 

Recommended 

Locations on 

Ceiling and Wall

Figure 5.  

 Separating the 

Detector from the Bracket

SMOKE TEST BUTTON

LED INDICATOR

CO TEST BUTTON

Figure 7. 

 Mounting the Smoke/CO detector

Figure 1.  

Locations 

for Placing Smoke/CO 

Detectors in a Single-

Floor Residence

Figure 2. 

 

Locations 

for Placing Smoke/CO 

Detectors in a Multi-

Floor Residence

GENERAL INFORMATION

FEATURES

FEATURES

WHERE TO INSTALL

WHERE NOT TO INSTALL

MOUNTING THE BRACKET

SLOPED CEILING INSTALLATION

CEILING OR WALL INSTALLATION

TESTING

INSTALLING THE BATTERIES

GENERAL MAINTENANCE

BATTERY

COMPARTMENTS