background image

Installer: Manual must 

remain with owner/operator.

Prior to installation, record information 

from pump nameplate for future reference:

Model:

7000 Apple Tree Avenue

Bergen, NY 14416

ph: 1-800-543-2550

fax: 1-585-494-1839

www.LibertyPumps.com

Keep this manual handy for future reference.

For replacement manual, visit LibertyPumps.com, 

or contact Liberty Pumps at 1-800-543-2550.

Retain dated sales receipt for warranty.

Serial:

Mfg Date:

Install Date:

Installation 

Manual

5672000J

Copyright © Liberty Pumps, Inc. 2021 All rights reserved.

For pressure sewer applications

, verify a Redundant Check Valve Assembly (curb stop and check valve) is installed between the pump 

discharge and the street main, as close to the public right-of-way as possible, on all installations to protect from system pressures.

RE/REX-Series

Omnivore® Grinder Pump Retrofit Unit

Fully assembled replacement package

Core replacement for:

E/One

®

 GP200 and GP2000

LSG202-RE

2 hp, 208/230V, 1-phase, Automatic

LSGX202-RE

2 hp, 208–230V, 1-phase, Automatic

E/One

® 

Extreme D-Series

LSG202-REX

2 hp, 208/230V, 1-phase, Automatic

LSGX202-REX

2 hp, 208–230V, 1-phase, Automatic

E/One® is a registered trademark of Environment One Corporation

Содержание Omnivore LSG202-RE

Страница 1: ...Pumps Inc 2021 All rights reserved For pressure sewer applications verify a Redundant Check Valve Assembly curb stop and check valve is installed between the pump discharge and the street main as clos...

Страница 2: ...r cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installa...

Страница 3: ...sin in accordance with local code Proper venting of sewer and effluent gases alleviates poisonous gas buildup and reduces the risk of explosion and fire from these flammable gases Wear adequate Person...

Страница 4: ...month should have impellers and cutters manually operated through the breaker panel once a month to lubricate the seals Pumps that are idle in a wet basin must be removed Pump Design LSG LSGX Series g...

Страница 5: ...nd national codes 5 Disconnect the electrical quick disconnect plug that is hanging in the basin if applicable 6 Remove bolts securing the current unit if applicable 7 Close valve on current unit 8 Se...

Страница 6: ...rcial Series models The date of purchase shall be determined by a dated sales receipt noting the model and serial number of the pump The dated sales receipt must accompany the returned pump if the dat...

Страница 7: ...5672000J Copyright Liberty Pumps Inc 2021 All rights reserved 7 EN technical specifications and manuals...

Страница 8: ...8 EN Copyright Liberty Pumps Inc 2021 All rights reserved 5672000J...

Отзывы: