Table 2. Troubleshooting Matrix

 

Problem

Possible Cause

Corrective Action

Pump does not start.

Control panel selector switch in Off position.

Set selector switch to Hand or Auto position.

Blown control circuit transformer fuse.

Replace fuse.

Tripped circuit breaker, blown fuse, or other 

interruption of power.

Reset tripped circuit breaker; replace blown fuse 

with properly sized fuse; investigate power 

interruption.

Improper voltage.

Have an electrician check all wiring for proper 

connections and adequate voltage and capacity.

Float switch is unable to move to the PUMP ON 

position due to interference in basin or other 

obstruction.

Position the pump or float switch so that it has 

adequate clearance for free movement.

Insufficient liquid level.

Verify the liquid level is allowed to rise enough 

to activate float switch(es).

Defective float switch.

Replace float switch.

Obstructed impeller or volute.

Remove obstruction.

Loose wiring connections.

Check and tighten all connections.

Thermal overload tripped.

Wait for pump to cool to operating 

temperature.

Pump does not deliver proper 

capacity.

Discharge gate valve partially closed or clogged.

Check the discharge line for foreign material, 

including ice if the discharge line passes 

through or into cold areas.

Check valve partially clogged.

Raise liquid level up and down to clear; remove 

check valve to remove obstruction.

Incorrect motor rotation.

1-phase: verify capacitor wiring in Figure

 

1, else 

consult factory.

3-phase: correct pump rotation direction. Refer 

to section 

3-Phase Pump Rotation 

Verification

.

Low liquid level.

Check liquid level.

Obstruction in pump or piping.

Remove obstruction.

Total head is beyond pump's capability.

Route discharge piping to a lower level. If not 

possible, a larger pump may be required. 

Consult Liberty Pumps.

Pump runs but does not turn off.

Pump is airlocked.

Turn pump off and let set for several minutes, 

then restart.

Float switch unable to move to the PUMP OFF 

position due to interference with the side of 

basin or other obstacle.

Position the pump or float switch so that it has 

adequate clearance for free movement.

Control panel selector switch in Hand position.

Set selector switch to Auto position.

Control panel failure.

Check control panel.

Defective float switch.

Replace float switch.

Missing or faulty curb stop/swing check valve 

allowing system pressure to feed back through 

discharge piping.

Verify presence of a curb stop check valve or 

replace curb stop/swing check valve assembly.

Содержание LGH02 Series

Страница 1: ...y as possible on all installations to protect from system pressures Installer manual must remain with owner or system operator maintainer Record information from pump nameplate Model Serial Control Pa...

Страница 2: ...wer cord This will damage the power cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power...

Страница 3: ...Proper venting of sewer and effluent gases alleviates poisonous gas buildup and reduces the risk of explosion and fire from these flammable gases Wear adequate Personal Protective Equipment when worki...

Страница 4: ...s will be according to the control selected see separate operation instructions supplied with the unit IMPORTANT When connecting an LEP Series pump to an existing control panel verify the panel is cor...

Страница 5: ...higher than the full load input power indicated on the pump nameplate Power and Control Cords Do not remove cord and strain relief and do not connect conduit to pump The power and control cords are fi...

Страница 6: ...that the cutter and impeller are freely spinning rotating the cutter helps to lubricate the shaft seals if the pump has been non operational for more than a week It is recommended to rotate the cutter...

Страница 7: ...200 PSI service See Liberty Pumps line of CSV Series Curb Stop Swing Check Valve Assemblies and CK Series Connection Kit Vent The fiberglass basin provided with the system must be completely sealed an...

Страница 8: ...ive Equipment when working on pumps or piping that have been exposed to wastewater Sump and sewage pumps often handle materials that can transmit illness or disease upon contact with skin and other ti...

Страница 9: ...valve partially closed or clogged Check the discharge line for foreign material including ice if the discharge line passes through or into cold areas Check valve partially clogged Raise liquid level...

Страница 10: ...heck valve Repeated tripping Circuit protection underrated Check rating and replace with proper size Current unbalance Check current draw Other appliance on same circuit Pump requires separate circuit...

Страница 11: ...the discharge line passes through or into cold areas Check valve is stuck closed or installed backward Remove check valve s and examine for freedom of operation and proper installation Gate or ball va...

Страница 12: ...der this Warranty if the product has not been properly installed or maintained in accordance with the printed instructions provided if it has been disassembled modified abused or tampered with if the...

Отзывы: