background image

2 | EN

Copyright © Liberty Pumps, Inc. 2022 All rights reserved.

7550000G

Contents

Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 | EN
Model Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
General Information   . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Operating Constraints  . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Inspection and Storage . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Pump System Components  . . . . . . . . . . . . . . . . . . . . . 5 | EN
Wiring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 | EN
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 | EN
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 | EN
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10 | EN
Maintenance and Troubleshooting . . . . . . . . . . . . . . 10 | EN
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14 | EN

Sa fety Guidelines

Sa fety  Preca utions

Always disconnect pump(s) from power source(s) before 

handling or making any adjustments to either the pump(s), 

the pump system, or the control panel.

Accidental contact with electrically live parts, items, fluid, or 

water can cause serious injury or death.

All installation and maintenance of pumps, controls, 

protection devices, and general wiring shall be done by 

qualified personnel.

All electrical and safety practices shall be in accordance with 

the National Electrical Code

®

, the Occupational Safety and 

Health Administration, or applicable local codes and 

ordinances.

Do not remove cord and strain relief, and do not connect 

conduit to pump.

Pump shall be properly grounded using its supplied 

grounding conductor. Do not bypass grounding wires or 

remove ground prong from attachment plugs. Failure to 

properly ground the pump system can cause all metal 

portions of the pump and its surroundings to become 

energized.

Do not handle or unplug the pump with wet hands, when 

standing on damp surface, or in water unless wearing 

Personal Protective Equipment.

Always wear dielectric rubber boots and other applicable 

Personal Protective Equipment (PPE) when water is on the 

floor and an energized pump system must be serviced, as 

submerged electrical connections can energize the water. Do 

not enter the water if the water level is higher than the PPE 

protection or if the PPE is not watertight.

Do not lift or carry a pump or a float assembly by its power 

cord. This will damage the power cord, and could expose the 

electrically live wires inside the power cord.

The electrical power supply shall be located within the length 

limitations of the pump power cord, and for below grade 

installations it shall be at least 4

 

ft (1.22

 

m) above floor level.

Do not use this product in applications where human contact 

with the pumped fluid is common (such as swimming pools, 

fountains, marine areas, etc.).

Protect the power and control cords from the environment. 

Unprotected power and control (switch) cords can allow water 

to wick through ends into pump or switch housings, causing 

surroundings to become energized.

Single-phase 200/230V pumps shall only be operated without 

the float switch by using the circuit breaker or panel 

disconnect.

Do not use an extension cord to power the product. Extension 

cords can overload both the product and extension cord 

supply wires. Overloaded wires will get very hot and can catch 

on fire.

This safety alert symbol is used in the manual 

and on the pump to alert of potential risk for 

serious injury or death.
This safety alert symbol identifies 

risk of 

electric shock

. It is accompanied with an 

instruction intended to minimize potential 

risk of electric shock.
This safety alert symbol identifies 

risk of fire

It is accompanied with an instruction 

intended to minimize potential risk of fire.
This safety alert symbol identifies 

risk of 

serious injury or death

. It is accompanied 

with an instruction intended to minimize 

potential risk of injury or death. 
Warns of hazards which if not avoided 

will

 

result in serious injury or death.
Warns of hazards which if not avoided 

could

 

result in serious injury or death.
Warns of hazards which if not avoided 

could

 

result in minor or moderate injury.
Signals an important instruction related to 

the pump. Failure to follow these instructions 

could result in pump failure or property 

damage.

Read every supplied manual before using 

pump system. Follow all the safety instructions 

in manual(s) and on the pump. Failure to do so 

could result in serious injury or death.

RISK OF ELECTRIC SHOCK

RISK OF FIRE

Содержание LGH Series

Страница 1: ... system pressures Installer manual must remain with owner or system operator maintainer Record information from pump nameplate Model Serial Control Panel Mfg Date Install Date Dealer Dealer Ph 7000 Apple Tree Avenue Bergen NY 14416 ph 1 800 543 2550 fax 1 585 494 1839 www LibertyPumps com LEP 60 Hz 7550000G LGV Series LGH Series Ordinary Location Models XLGV Series XLGH Series Approved for Hazardo...

Страница 2: ...wer cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installations it shall be at least 4 ft 1 22 m above floor level Do not use this product in applications where human contact with the pumped fluid is common such as swimming pools fountains marine areas etc...

Страница 3: ... careful around pump base while power is connected Make sure that the pump is either in the tank or clear from people and wires when in operation Wear adequate Personal Protective Equipment when working on pumps or piping that have been exposed to wastewater Sump and sewage pumps often handle materials that can transmit illness or disease upon contact with skin and other tissues Do not enter a pum...

Страница 4: ...t trim impellers without consulting the factory Model Specifications For complete listing of models and their specifications refer to www LibertyPumps com lep About Engineering Specs Pump nameplate provides a record of specific pump information Inspection and Storage Initial Inspection The pump should be immediately inspected for damage that may have occurred in shipment 1 Visually check the pump ...

Страница 5: ...onents can be purchased separately using the part numbers shown Other options such as pre wired kits are also available Control Panels in Hazardous Locations Float switches must be connected to an intrinsically safe circuit in the control panel as per the requirements of Chapter 5 of the National Electric Code For hazardous locations the control panel must be installed outside the hazardous area a...

Страница 6: ... the pump will continue to operate but service should be scheduled as soon as possible The LEP Series control panels by Liberty Pumps have a seal leak detection system with a test button that monitors the integrity of the seal leak circuit and components When pressed the light should illuminate The light should go off when the test button is released If it remains on the potentiometer is set too h...

Страница 7: ...K POTTING RESIN RED WHITE ORANGE RUN CAP 80 MFD 370 VAC START CAP 270 324 MFD 330 VAC SEAL LEAK POWER CORD CONTROL CABLE ORANGE RED RED WHITE WHITE GREEN GREEN BLACK BLACK THERMOSTAT M3 M2 M1 L3 L2 L1 MOTOR GRAY BROWN BROWN GREEN GRAY THERMOSTAT SEAL FAILURE PROBES POTTING RESIN FOR HAZLOC PUMPS M3 M2 M1 1 6 7 2 4 8 3 5 9 200 230V 3PH 2D 460V 3PH 1D 15HP MODELS ONLY M3 M2 M1 1 1 2 2 3 1 2 3 3 7 7 ...

Страница 8: ...e 1 and Figure 2 Figure 1 Cut off Point 3 7 hp Pumps Figure 2 Cut off Point 10 15 hp Pumps Cutter and Impeller Free Movement Check Wear Personal Protective Equipment to protect hands as cutter blades have extremely sharp edges and present a serious cutting hazard Do not connect any power to pump until this check is complete Manually rotate the cutter and impeller to check that they spin freely wit...

Страница 9: ... as short as possible with a minimum number of turns to minimize friction head loss Do not reduce the discharge to below the pump outlet size Larger pipe sizes may be required to eliminate friction head loss over long runs Contact Liberty Pumps or other qualified person if questions arise regarding proper pipe size and flow rates Pressure Sewer Applications A redundant check valve assembly consist...

Страница 10: ...le of operation 7 Turn H O A switch es to OFF position and allow basin to fill to the override alarm control level s 8 Observe all floats in operation to verify that there is adequate clearance to the surrounds to ensure that the floats do not have the opportunity to get hung up in their travel 9 Verify alarm system response 10 Turn switch es to AUTO position pumps should start and operate togethe...

Страница 11: ...ps The only allowable repairs replacements without compromising the hazardous location rating of the pump are Quick connect cords lower outer shaft seals volute and impeller components Otherwise the pump must be returned to Liberty Pumps or an authorized hazardous repair facility for electrical and motor service This will ensure the integrity of the hazardous location rating of the pump and comply...

Страница 12: ...ctive float switch Replace float switch Missing or faulty curb stop swing check valve allowing system pressure to feed back through discharge piping Verify presence of a curb stop check valve or replace curb stop swing check valve assembly Pump operates with selector switch in Hand position but does not operate in Auto position Control circuits malfunctioning Check float switch level control or al...

Страница 13: ...essure to feed back through discharge piping Verify presence of a curb stop check valve or replace curb stop swing check valve assembly Pump runs periodically when fixtures are not in use Check valve not installed stuck open or leaking Install check valve s remove check valve and examine for freedom of operation and proper installation Fixtures are leaking Repair fixtures as required to eliminate ...

Страница 14: ... gravel or other abrasives if the product has been used to pump chemicals or hydrocarbons if the product has been moved from its original installation location or if the label bearing the serial and code number has been removed Liberty Pumps Inc shall not be liable for any loss damage or expenses resulting from installation or use of its products or for consequential damages including field labor ...