background image

                            

©Copyright 2011 Liberty Pumps Inc.    All rights reserved                                                             1 

 

IMPORTANT: 

Prior to installation, record Model, Serial Number, and 
Code Number from pump nameplate for future reference. 

MODEL    ________________________

 

SERIAL   ______________________ 

CODE      ______________________ 

INSTALLATION 
DATE       _______________________ 

 
 
 
 
 
 

Installation Manual 

 

                                                                  7353000E 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

Features: 

 

36” Diameter Fiberglass Tank 

 

Available in 48”, 60”, 72”, 84”, and 96” heights 

  LSG Single or LSGX 2 Stage 2HP Grinder Pumps 

  Factory Installed Guide Rail System 

  Quick Tree

™ pre-mounted float system 

  NEMA 4X Junction Box 

  NEMA 4X Duplex Alternating Control Panel 

Contents 

 

1.  General Information 

2.  Precautions / Pre-Installation 

3.  Installation Instructions 

4.  Maintenance & Troubleshooting 

5.  GR20 Assembly 

D3600- Series Duplex Grinder Systems 

7000 Apple Tree Avenue  
Bergen, NY  14416      
Phone: (800) 543-2550     
Fax: (585) 494-1839 
www.libertypumps.com 

Содержание D3600- Series

Страница 1: ...000E Features 36 Diameter Fiberglass Tank Available in 48 60 72 84 and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory Installed Guide Rail System Quick Tree pre mounted float system NEMA 4X Junction Box NEMA 4X Duplex Alternating Control Panel Contents 1 General Information 2 Precautions Pre Installation 3 Installation Instructions 4 Maintenance Troubleshooting 5 GR20 Assembly D36...

Страница 2: ...ion and installation of the basin but it does not cover the specifics of the pump operation or the control panel operation If you have any questions call customer service at 800 543 2550 2 Precautions Pre Installation Risk of electric shock Always disconnect the pump from the power source before handling or making adjustments These pumps are not to be installed in locations classified as hazardous...

Страница 3: ...rovide a solid level base that can support the weight of the filled basin If a concrete pad will be used under the basin the compacted stone sub base can be reduced to 6 inches 2 Connections Backfill Pour enough concrete over and around the anti floatation flange to anchor the basin and prevent upward movement Connect 2 schedule 80 PVC pipe to the pump discharge Do not reduce the size of the disch...

Страница 4: ... loosen the cord nut and pull the tree straight out of the tank The pump cycle is pre set at the factory at 12 for D3648 approximately 53 gallons and 18 for D3672 approximately 79 gallons The pump cycle can be adjusted by loosening the cord clamp and moving the on float up or down We do not recommend adjustments of more than 3 in either direction please call the factory if you need to adjust the p...

Страница 5: ...ctly it will seal and provide a means to lift the pump without disconnecting any of the discharge piping Please ensure that installation is done as per the diagrams below DISCONNECTED POSITION PIPE GUIDE ASSEMBLY OPERATING POSITION 1 1 4 GUIDE RAIL PIPE 1 1 4 DISCHARGE PIPE INSTALL 3 8X16 HEX BOLTS HERE EVENLY TIGHTEN BOTH SIDES SO THAT GASKET IS PROPERLY COMPRESSED ENSURE THAT RUBBER GROMMET IS P...

Страница 6: ...rer shall not be liable under this Warranty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduced in size if the pump has been used in water containing sand lime cement gravel or other abrasives if the pump has been used in water above the advertised t...

Отзывы: