The ALM-2R alarm system features a battery operated wireless transmitter that is placed in a tank (up to 150 feet away from the 
indoor alarm). When the high water alarm fl oat switch activates, the transmitter sends a signal and sounds the indoor alarm warning 
of a potentially threatening liquid level condition. The horn can be silenced, but the alarm light remains on until the condition is 
remedied. Once the condition is cleared, the alarm will automatically reset.

The ALM-2R alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, 
effl uent fi lters, and other water applications.

ALM-2R (Wireless) Alarm Installation Instructions

  120 VAC Voltage -

  Primary:  120  VAC,  60  Hz,  2.4  watts  maximum  (alarm  condition);  Operating  Voltage:  9  VDC.                                                                                                                                

  NEMA 1 enclosure rated for indoor use.

  Automatic alarm reset.

  Red "alarm" light and green "power on" light, alarm "test" switch, and horn "silence" switch.

  6 foot (1.8 meter) power cord.

  Alarm horn sounds at 87 decibels at 10 feet (3 meters).

  If primary power fails, the alarm system continues to work due to battery backup feature.

 

Battery Backup Power:          

9 VDC (Battery not included.)

  Package includes standard SJE MilliAmpMaster™ with 10 feet (3.04 meters) of cable with transmitter.

  Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock.

  Low battery chirp.

  Loss of signal alarm. After 24 hours without a signal the red LED will fl ash. After 7 days without a signal the alarm will 

sound.  

  External terminal block for an optional local alarm fl oat.

ALM-2R ALARM FEATURES

ALM-2R TRANSMITTER FEATURES

  Wireless transmitter with up to 150 foot range 

 

    Meets all FCC requirements

  Long life 3.6V lithium battery (recommended replacement 2 years)   

    Transmitter transmits once per hour or when    

 

 

        the fl oat position is changed.            

                                                                                        

pump discharge has been reduced in size; if the pump has 
been used in hot water or water containing sand, lime, cement, 
gravel, or other abrasives; if the product has been used to pump 
chemicals or hydrocarbons; if a non-submersible motor has be 
subject to excessive moisture; or if the label bearing the serial 
and code number has been removed.

Liberty Pumps, Inc. shall not be liable for any loss, damage 
or expenses resulting from installation or use of its products, 
or for consequential damages, including costs of removal, 
reinstallation or transportation.

There is no other express warranty. All implied warranties, 
including those of merchantability and fi tness for a particular 
purpose, are limited to three years from date of purchase.

The Warranty contains the exclusive remedy of the purchaser, 
and, where permitted, liability for consequential or incidental 
damages under any and all warranties are excluded.

LIBERTY PUMPS THREE-YEAR LIMITED WARRANTY

Liberty Pumps, Inc.

 warrants that products of its manufacture 

are free from all factory defects in material and workmanship 
for a period of 3 years from the date of purchase. The date of 
purchase shall be determined by a dated sales receipt noting 
the model and serial number. The dated sales receipt must 
accompany the returned product if the date of return is more 
than 3 years from the date of manufacture noted on the product. 

The manufacturer’s obligation under this Warranty shall be 
limited to the repair or replacement of any parts found by the 
manufacturer to be defective, provided the part or assembly is 
returned freight prepaid to the manufacturer or its authorized 
service center, and provided that none of the following warranty-
voiding characteristics are evident:

The manufacturer shall not be liable under this Warranty if 
the product has not been properly installed; if it has been 
disassembled, modified, abused or tampered with; if the 
electrical cord has been damaged or improperly spliced; if the 

PREVENTATIVE  MAINTENANCE

•  

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the preformance of the product.  

 

Replace the product immediately if any damage is found or suspected.

•  

Periodically check to see that the fl oat is free to move and operate the switch.

• 

Replace batteries as specifi ed in instructions. 

• 

Use only Liberty Pumps replacement parts.

Содержание ALM-2R

Страница 1: ...micals or hydrocarbons if a non submersible motor has be subject to excessive moisture or if the label bearing the serial and code number has been removed Liberty Pumps Inc shall not be liable for any...

Страница 2: ...each alarm condition to ensure proper operation If battery is low the low battery chirp feature will cause the horn to chirp approximately once per minute Replace battery if this occurs Note Non alkal...

Страница 3: ...hforreliableoperation Movereceiverto a different location Note A change in location as minor as moving it up vertical one foot could allow it to operate reliably 9 Replace battery every 2 years ALARM...

Страница 4: ...to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception...

Страница 5: ...ilizada en agua caliente o en agua que conten a arena cal cemento gravilla u otros abrasivos si el producto fue utilizado para bombear productos qu micos o hidrocarburos si un motor no sumergible ha e...

Страница 6: ...r su funcionamiento adecuado Silabater aest baja elsonidoaudiblecaracter stico har que el parlante de la alarma chirr e tonos cortos y agudos aproximadamente una vez por minuto Reemplace la bater a si...

Страница 7: ...el receptor a un sitio diferente Nota un peque o cambio de sitio por ejemplo verticalmente hacia arriba unos 12 cent metros podr a permitir su buen funcionamiento 9 Remplace la bater a cada 2 a os C D...

Страница 8: ...rucciones podr a provocar interferencias perjudiciales a las radiocomunicaciones Sin embargo no se garantiza la ausencia de interferencia en una determinada instalaci n Si el equipo produce interferen...

Страница 9: ...ant du sable de la chaux du ciment du gravier ou autre produit abrasif si le produit a t utilis pour pomper des produits chimiques ou des hydrocarbures si un moteur non submersible a t soumis de l hum...

Страница 10: ...n 120 V et 9 V c c Retirer la pile de 3 6 V c c de l metteur Remettre sous tension le r cepteur Ne pas ins rer la pile de l metteur pour le moment 13 Remplacer la pile 9 V c c chaque de 12 mois et apr...

Страница 11: ...ent diff rent Remarque Un changement d emplacement si mineur soit il tel un d placement de 30 cm 1 pied la verticale peut permettre un fonctionnement fiable 9 Remplacer la pile tous les 2 ans BOUTON D...

Страница 12: ...aux communications radio N anmoins il n est pas possible de garantir qu aucune interf rence ne se produira dans une installation particuli re Si l quipement cr e des interf rences nuisibles la r cepti...

Отзывы: