GraphIt
Selecting Observations
12-10
Using the LI-6400
12
If you enter * (or any non-numeric entry, for that matter) for either the max
or min value, that parameter will be computed for you, based on the variables
defined for that axis.
Storing Plot Definitions
The
Store Config
function key (
f5
level 1) allows you to store the current plot
definition for later recall using the
QuikPik Config
function key (
f1
level 1).
Definitions should be stored in the directory
/User/Configs/PlotDefs
. The directo-
ry and file name are obtained from you by GraphIt using the Standard File Di-
alog.
Selecting Observations
GraphIt provides three tools for selecting data subsets for plotting or viewing.
In order of priority of implementation, they are:
1
First and Last Data Lines
Data is found by searching for non-blank lines whose first character is not a
quote ("), starting with the First Data Line. The search continues until a blank
line is found, or until the Last Data Line has been searched.
2
Use Every nth Line
Between the First and Last Data Lines, every
n
th
line is converted to numbers,
provided it does not start with a quote ("). The default value of
n
is 1, but the
user can set this. This is useful for subsampling large data files.
3
Inclusion Based On Data Values
Once a line is converted to numbers, any variable(s) or combination thereof
can be tested to see if that observation should be included.
Picking the First and Last Observation
The starting and ending data lines can be manually selected. Press Ò
Data Set
Pick
Ó (
f1
level 2), then
P
. You will be prompted to select three lines in suc-
cession using Standard Menu: the label line, the first data line, and the ending
data line (Figure 12-9).
Note:
The axes max and min arenÕt the actual data values
max and min. The axes are scaled a bit larger to encompass
the plotting symbols.
Содержание LI-6400
Страница 1: ...Using the LI 6400 Portable Photosynthesis System ...
Страница 15: ...Part I The Basics ...
Страница 16: ......
Страница 174: ...Making Measurements Answers to Questions 4 56 Using the LI 6400 4 ...
Страница 175: ...Part II Useful Details ...
Страница 176: ......
Страница 200: ...Standard Tools Power ON Hooks 5 24 Using the LI 6400 5 ...
Страница 214: ...Real Time Data Real Time Graphics 6 14 Using the LI 6400 6 ...
Страница 234: ...Environmental Control Light Control 7 20 Using the LI 6400 7 ...
Страница 244: ...Light Sensor Considerations Gallium Arsenide Phosphide GaAsP Sensor 8 10 Using the LI 6400 8 ...
Страница 288: ...Data Logging Making Your Own AutoPrograms 9 44 Using the LI 6400 9 ...
Страница 289: ...Part III Working With Files ...
Страница 290: ......
Страница 312: ...The LPL File System Troubleshooting 10 22 Using the LI 6400 10 ...
Страница 340: ...Downloading Files Using a Data Capture Program 11 28 Using the LI 6400 11 ...
Страница 375: ...Part IV Configuration Issues ...
Страница 376: ......
Страница 420: ...Defining User Variables Old Style vs New Style 15 18 Using the LI 6400 15 ...
Страница 454: ...Using an Energy Balance Further Reading 17 12 Using the LI 6400 17 ...
Страница 455: ...Part V Maintenance Troubleshooting ...
Страница 456: ......
Страница 572: ...Troubleshooting Useful Information 20 46 Using the LI 6400 20 ...
Страница 587: ...Diagnostics and Utilities Sys Utility Programs Using the LI 6400 21 15 EBVpd t C guess EBSatVap _EBvap_kPa ...
Страница 593: ...Part VI Programming ...
Страница 594: ......
Страница 622: ...Programming with LPL Compiler Directives 22 28 Using the LI 6400 22 ...
Страница 846: ...Index I 16 Using the LI 6400 ...