GraphIt
Defining Plots
Using the LI-6400
12-9
¥
R: Change Range
Pressing
R
(Figure 12-6 on page 12-8) will allow the max and min to be spec-
ified for the axis being edited. If available, the range of the data will be dis-
played for your information.
"Obs" 1
"Time" 2
"Photo" 3
"Ci" 5
"Trmmol" 6
"VpdL" 7
"Cond" 4
X Axis
Pick 1 variable.
"Obs" 1
"Time" 2
"Photo" 3
"Ci" 5
"Trmmol" 6
"VpdL" 7
"Cond" 4
Y Axis plot #1
Pick up to 5 vars:
Press ENTER for each
(or Õ0Õ - dot2dot
or 1 to 5 for poly fit)
Press <esc> to stop.
Selecting Y or Z variables
Selecting the X variable
Figure 12-7. Selecting the variable(s) for an axis is done via Standard Menu. Y and Z axes allow up to five vari-
ables to be included, and provide a short-cut for doing curves. When youÕve selected all the variables you want,
press
escape
.
The X variable is selected from a
menu of all the data columns in
the data file.
The Y or Z variable(s) are se-
lected from the same menu. A
shortcut is provided for drawing
curves: press a number rather
than enter to make a selection.
Also, up to 5 entries can be se-
lected. Press escape after you
have selected all the ones you
want.
The variable count for that axis.
Up to 5 can be selected.
Data range is 27.1 to 769
Enter MIN (* to autoscale)
0
Enter MAX
*
+ DelLn
¨
ClrEnd
¨
DelChar
¨
CapLock
¨
AnyChar
Figure 12-8. An axisÕs min and max are prompted for in sequence, with
the default value or response displayed.
Содержание LI-6400
Страница 1: ...Using the LI 6400 Portable Photosynthesis System ...
Страница 15: ...Part I The Basics ...
Страница 16: ......
Страница 174: ...Making Measurements Answers to Questions 4 56 Using the LI 6400 4 ...
Страница 175: ...Part II Useful Details ...
Страница 176: ......
Страница 200: ...Standard Tools Power ON Hooks 5 24 Using the LI 6400 5 ...
Страница 214: ...Real Time Data Real Time Graphics 6 14 Using the LI 6400 6 ...
Страница 234: ...Environmental Control Light Control 7 20 Using the LI 6400 7 ...
Страница 244: ...Light Sensor Considerations Gallium Arsenide Phosphide GaAsP Sensor 8 10 Using the LI 6400 8 ...
Страница 288: ...Data Logging Making Your Own AutoPrograms 9 44 Using the LI 6400 9 ...
Страница 289: ...Part III Working With Files ...
Страница 290: ......
Страница 312: ...The LPL File System Troubleshooting 10 22 Using the LI 6400 10 ...
Страница 340: ...Downloading Files Using a Data Capture Program 11 28 Using the LI 6400 11 ...
Страница 375: ...Part IV Configuration Issues ...
Страница 376: ......
Страница 420: ...Defining User Variables Old Style vs New Style 15 18 Using the LI 6400 15 ...
Страница 454: ...Using an Energy Balance Further Reading 17 12 Using the LI 6400 17 ...
Страница 455: ...Part V Maintenance Troubleshooting ...
Страница 456: ......
Страница 572: ...Troubleshooting Useful Information 20 46 Using the LI 6400 20 ...
Страница 587: ...Diagnostics and Utilities Sys Utility Programs Using the LI 6400 21 15 EBVpd t C guess EBSatVap _EBvap_kPa ...
Страница 593: ...Part VI Programming ...
Страница 594: ......
Страница 622: ...Programming with LPL Compiler Directives 22 28 Using the LI 6400 22 ...
Страница 846: ...Index I 16 Using the LI 6400 ...