Help Hot Line (U.S. only): 1-800-530-9960
4-5
D-620605-0-20 Rev A
CONFIDENTIAL
Remote Access Unit Specifications
4.4
Remote Access Unit Specifications
NOTE:
For system performance, it is important that you use only low loss,
solid copper center conductor CATV cable with quality F connectors that use
capture centerpin conductors. Refer to Appendix A for more information.
Table 4-3
Remote Access Unit Specifications
Specification
Description
Dimensions (H
×
W
×
D)
133.5 mm × 438 mm × 381 mm
(5.25 in. × 17.25 in. × 15 in.)
Weight
< 2.1 kg (< 4.6 lb.)
Operating Temperature
–25° to +45°C (–13° to +113°F)
Non-operating Temperature
–25° to +85°C (–13° to +185°F)
Operating Humidity, non-condensing
RF Connectors
1 F, female (CATV - 75 ohms)
LED Alarm and Status Indicators
Maximum Heat Dissipation (W)
50 typical, 64 max (from the Hub)
MTBF
211,600 hours