36
206-4310
0 = Aux
127 = Map to Major CH 4
1 – 125 = Major Ch. #
253 = IP Start Channel
126 = Map to Major CH 3
255 = Last Channel
Note:
126 and 127 are mapped only in SONIFI PPV Mode.
Note:
If setting this item to 0 (Aux), make sure to also set item 046
STRT AUX SRCE to the appropriate value.
Note:
The IP Start Channel shown above can only be set in the
FTG File Manager, which is used to configure STB CPUs for FTG
Mode. The same applies for the additional Major Channel number
range of 128 – 135 in Physical tuning and 128 – 999 in Virtual tuning
mode. This means that these values, if set, will only be visible in
the read-only Installer Menu when the STB is in FTG Mode. The
read-only display also will show additional information about the
channel, for example, the IP address and port number, etc.
005 - CHAN LOCK (Channel Lock)
Channel Lock is ideal if the system must always be on the same
channel. Changing channels with the Channel Up/Down or keypad
numbers is impossible. Channel Lock is inactive if set to 0 (default).
Generally, this feature is used in connection with item 004 STRT
CHANNEL where the Start Channel may, for example, be set to 3
or 4. If the Start Channel is 3, then the STB will remain locked on
channel 3.
NOTE:
For items 007, 008, and 009
For legacy reasons, the scale used is 0 – 63. The PTC software
will translate this to the 0 – 100 scale used by the STB.
To translate an STB volume level to the Installer Menu value,
use the following formula:
Installer Value = STB Value x 63
100
Enter only the whole number (disregard fractions).
007 - STRT VOLUME (Start Volume)
This function allows the Installer to determine the initial volume
level setting when the STB/display panel is turned ON. This feature
is useful for an in-house information channel, since the STB/display
will always select that volume level when it is turned ON. The range
of values is 0 to 63, 255. If set to 255, the last volume level before
the STB/display was turned OFF will be the current volume level
when the STB/display is turned ON again.
008 - MIN VOLUME (Minimum Volume)
This function determines the minimum volume level allowable
with the Volume (VOL) Up/Down control. In this way, for example,
someone cannot set the volume too low to hear. The value range
is from 0 to 63. The factory default is 0, which provides the full
range of volume control, if item 009 MAX VOLUME is set to 63. It
is recommended to set the same value on every STB.
Note:
The minimum volume level cannot have a value setting
higher than the maximum volume level (described below).
009 - MAX VOLUME (Maximum Volume)
This function determines the maximum volume level allowable
with the Volume (VOL) Up/Down control. In this way, for example,
someone cannot set the volume level high enough to disturb others.
The value range is 0 to 63, with 63 as the default, which gives the
user the full range of volume control, if item 008 MIN VOLUME is
set to 0. It is recommended to set the same value on every STB.
Note:
The maximum volume level cannot have a value setting
lower than the minimum volume level (described above).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot
be muted. If set to 0, sound can be muted.
011 - KEY DEFEAT
Applicable for LG Hospitality and commercial non-LG display
panels only. If set to 1, Key Defeat is enabled, which means that
end users cannot access or navigate within the STB’s on-screen
menu(s) from the display panel; i.e., menu navigation buttons will
not function. Set to 0 to disable Key Defeat. Note that all IR features
remain functional regardless of this setting; users can always
access the STB’s menus by pressing MENU on the remote.
Note:
This feature does not apply to LG Public Displays or LG
Commercial Monitors since the STB will always disable those
displays’ panel buttons and the processing of IR.
015 - SLEEP TIMER
If set to 1, the Sleep Timer feature may be used. If set to 0, the
Sleep Timer is not available.
016 - EN. TIMER (Enable On/Off Timers)
If set to 1, the Timer function is available to the end user and
enabled continuously. Set to 0 to disable On/Off timers.
Note:
The STB clock must be set in order for timers to be used.
017 - ALARM
Gives the installer the option of making the Alarm function available
to the end user. If set to 1, the Alarm function is available to the end
user. Set to 0 to disable the Alarm function.
Note:
The STB clock must be set before the Alarm function will
work.
020 - FEATURE LEVEL
Determines an additional IR code scheme to which the STB will
respond, allowing for the use of unique IR codes based on “bed
number” in a multi-STB/display single room installation. First
determine the IR mode; then select the bed number.
Values
IR Mode
Bed #
0
Disabled
N/A
16 – 24
Multi-code Remote
1 – 9
Note:
The STB-dedicated Installer Remote is required for use of
this feature. For further information, see Reference section, “STB
Installer Remote.”