36
PROGRAMMING MODE
1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
Checking point
display
None
LqC 1
1 time
Check the version and code of
machine.
■
ELECTRIC TYPE : P3 OE
■
GAS TYPE : P3 Og
Version and code of machine (All LED on)
Display P3:OE or P3:Og and gU:XX alternately. XX is the
version number.
2 time
PDA CHECK
Ir--
3 time
Motor runs.
Measured moisture value (70~239)
4 time
■
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
■
GAS TYPE: Motor Runs.
Motor
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
5 time
■
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
■
GAS TYPE: GAS valve runs.
Motor+Valve
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
6 time
LED & KEY CHECK
Press High Temp. button.
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button
Version and code of machine
7 time
Test ends.
LqC1
During check, if the
door is open.
Door switch
(Motor & Heater Off, Buzzer beeps
seven times)
dE
(The door is open. Please close the door completely)
During check, if the
door is closed
Test goes back at step 2.
(Motor on & Heater Off )
Measured moisture value (70~239)
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
NOTE
PROGRAMMING MODE - Test Mode
diagnostic tests :
(display)
This program has been added for testing the dryer and detecting errors.
Entering the test mode
data Name
Button
display
description
Entering the
test mode
1. Entering
programming
mode
Insert service card (card type)Turn on/off toggle switch (coin type)
Push and hold the High Temp. and Low Temp. at the same time.
After that push Med Temp. button for 3 times. Push Start button.
(OPL type)
2. High Temp.
Press the High Temp. button.Then
appears in the display.
3. Start
Enter the diagnostic test mode.