Web based Power Distribution Indicator

(PQCPM11A0)

Installation/Owner's Manual

LG

Caution

• Read this manual thoroughly before installing the product.
• Only the certified professional should install this product.
• Keep this manual for referring during the operation later.

Содержание PQCPM11A0

Страница 1: ...n Indicator PQCPM11A0 Installation Owner s Manual LG Caution Read this manual thoroughly before installing the product Only the certified professional should install this product Keep this manual for referring during the operation later ...

Страница 2: ...b PDI at the installation site 2 4 Connecting RS485 cable to Web PDI 2 5 Connecting Ethernet cable to Web PDI 2 6 Connecting Power adaptor to Web PDI 2 7 Configuring the Web PDI network 2 8 Before configuring the Web PDI environment 2 8 Setting the IP address 2 12 Setting the gateway address 2 13 Setting the netmask address 2 14 Checking the network environment 2 15 Configuring the ACCS access 2 1...

Страница 3: ...l 3 3 Functions of ACCS 3 1 Monitoring the air conditioner status 3 1 Monitoring power consumption 3 2 Setting the system 3 6 4 Reference 4 1 Troubleshooting 4 1 Guide for Open source software 4 1 UTP cable connection chart 4 2 ...

Страница 4: ... by the installation work without the installation certification for which our company does not offer the free of charge service Using the product ignoring the note for safety may cause the misoperation of the product which may cause the body s injury or the damage of the product The note for safety is classified into two following items The symbols used at this manual have the following meanings ...

Страница 5: ...Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 Consult the service center or the professional installation agency about reinstalling the installed product The non professional may cause electric shock explosion or injury The flammable gas or the combustible substance such as gasoline benzene and thinner should not be ...

Страница 6: ... NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 Do not let water flow into the product It may cause electric shock and failure Do not put heavy weight on the power cord It may cause fire or electric shock Do not put heavy weight on the product It may cause the failure of the product LG N...

Страница 7: ...thernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 Do not use strong detergent such as...

Страница 8: ...nsumed by AC for some period up to 3 months Such information is available on the web site provided by Web PDI Main functions of the Web PDI are as follows Easy setting of IP address by using external buttons Indication of current power in use by individual A C or group Indication of accumulated power for period by individual A C Accumulation of total power consumption Web accessible GUI Note This ...

Страница 9: ...Also the demand control feature to control the demand power is controlled by directly connecting the Web PDI to the demand controller without installing a separate PC program LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 Web PD...

Страница 10: ...ction RS485 communication port connecting to the PDI to connect the airconditioner 4EA in total RS485 communication port for external extension RS485 communication port spar for exter extension 2EA in total Ethernet port for connecting the Internet The Ethernet port for connecting the Internet Ethernet port spare Ethernet port spare for the function extension of the Web PDI RS232 port RS232 port f...

Страница 11: ...X RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 LG Web PDI Web based Power Distribution Indicator Adaptor for Power supply Input 100 240V AC 50 60Hz 1 5A Output DC 12V 3 33A 40W MAX Power Cord International Standard IEC320 C14 Type Web PDI Installation Owner s Manual Caution Using the standardized part We are not responsible for any problem caused by using the adapt...

Страница 12: ...t RS485 port PDI communication port 4EA External device connection port 2EA RS 232 communication port Port for updating the program 1EA Ethernet port for Internet connectioin 1EA 10Base T Spare 1EA LED 20EA for displaying RS communication status Ethernet communication status RS232 communication status Power operation status LCD 16x2 Character displaying Network environment setting and information ...

Страница 13: ...the of CN_PC and RX line to the of CN_PC on the PDI s PCB STEP 3 Configure the IP and G W address of Web PDI STEP 4 Configure the SETTING in out door address on the web site of Web PDI STEP 5 Verify whether the value of PDI and the value on the website of Web PDI are identical or not 2 Installing Web PDI Caution Installing the Web PDI The Web PDI installation work needs the professional technique ...

Страница 14: ...rt End 7C 7F Address setup BMS or LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 Web PDI LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD T...

Страница 15: ...ter WHITE BLACK B R X T X A CN WATTMETER CN_OUT FAN CN_PC The color and polarity of the communications line can differ from what s indicated on the PCB depending on the manufacturer of watt meter Black white LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Страница 16: ...installation method of the Web PDI is described with the example installing the Web PDI at the wall 1 Decide the space to install the Web PDI Before installing the Web PDI check whether the place is suitable for connecting the Web PDI and the RS485 cable 2 Use the screw driver to fix them at the wall It can be fixed as shown at the following figure according to the installation place Fixing the We...

Страница 17: ... possible to be connected to the Web PDI to the TX Next connect the end of the RS485 cable connecting to the BUS_B of the PDI to the RX 2 The RS485 cable connecting to the PDI to the LG NET port RS485 port of the Web PDI Connect the connector connecting the RS485 cable to one of the ports LG NET1 LG NET4 The number of LG NET ports is 1 4 and it is possible to connect to any of them to use Connecti...

Страница 18: ...LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 1 ACT LNK 2 ACT LNK e n er TX RX TX RX Connecting to the hub Direct cable Connecting to the AC Manager Cross cable Caution Ethernet cable type It should be identified whether the Ethernet cable to be connected is the direct cable or the c...

Страница 19: ...5 16 17 18 19 20 DO 1 2 3 4 K Console Run Power TX RX Connecting Power adaptor to Web PDI After connecting the Ethernet cable the power adaptor should be connected for supplying the power to the Web PDI 1 Connect the power adaptor supplied with the Web PDI product to the power adaptor connection port of the ACT as shown at the below figure 2 After connecting the power adaptor connect the power cor...

Страница 20: ...eb PDI information and the menu are displayed at the LCD and the menu can be changed and selected by pressing MENU SELECT button and Up Down Left Right buttons Before configuring the Web PDI environment LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1...

Страница 21: ...twork environment of the Web PDI When the power switch is turned on the Web PDI booting screen is displayed on the LCD as shown at the below figure and when booting is completed the initial Web PDI screen is displayed LG Electronics Wait for booting Web PDI SW ver 1 0 0 Web PDI booting screen Initial Web PDI screen After booting Note Software version The software version of the current Web PDI is ...

Страница 22: ... displayed as shown below Select the desired function by pressing the left right button Whenever the left right button is pressed the menu is changed as shown below MENU SELECT MENU Set IP Address MENU Set IP Address MENU Set GW Address MENU Set Update Svr MENU Set Netmask Offered later not at present Enter the IP address Enter Gateway address Enter Netmask Press the MENU SELECT button at the desi...

Страница 23: ...hen pressing the down button MENU SELECT Set IP Address 192 168 000 000 Set IP Address 192 167 000 000 MENU SELECT Set IP Address 192 168 000 000 Set IP Address 192 168 000 000 Set IP Address 192 168 000 000 Set IP Address 192 148 000 000 Cannot be set Possible to set after setting the next digit to less than or equal to 4 When pressing the right button Also in order the sum of three numbers not t...

Страница 24: ...k MENU SELECT button Example to set IP address Set IP Address 192 168 002 101 MENU SELECT Web PDI SW ver 1 0 0 MENU SELECT MENU Set IP Address Set IP Address 192 168 000 000 MENU SELECT Click MENU SELECT button Example to set IP address Set IP Address 192 168 002 101 MENU SELECT Web PDI SW ver 1 0 0 2 Use Up Down Left Right button to enter the desired IP address 3 After entering the IP address pre...

Страница 25: ...layed MENU SELECT MENU Set GW Address Set GW Address 192 168 000 000 MENU SELECT Click MENU SELECT button Example to set Gateway address Set GW Address 165 186 002 001 MENU SELECT Web PDI SW ver 1 0 0 2 Use Up Down Left Right button to enter the desired gateway address 3 After entering the gateway address press the MENU SELECT button to set the entered gateway address But there is no MENU SELECT b...

Страница 26: ...ed MENU SELECT MENU Set Netmask Set Netmask 255 255 255 000 MENU SELECT Click MENU SELECT button Example to set Netmask address Set Netmask 255 255 255 000 MENU SELECT Web PDI SW ver 1 0 0 2 Use Up Down Left Right button to enter the desired net mask address 3 After entering the netmask address press the MENU SELECT button to set the entered netmask address But there is no MENU SELECT button press...

Страница 27: ...en press Left Right button to display the following Information screen Press the MENU SELECT button again The currently set network information can be checked Each different information is displayed on the LCD screen about every 3 seconds It is displayed as follows MENU SELECT MENU Information MAC Address 001B 1987 7B14 1023 Click MENU SELECT button MAC Address 001B 1987 7B14 1023 IP Address 165 1...

Страница 28: ...u don t know the access IP of the Web PDI check the Web PDI setup IP by referring to Chapter 2 Configuring the Web PDI network Checking the network environment Enter Web PDI access IP 2 Installing Web PDI Configuring indoor units information on ACCS If previous installation step is done next step should be configuration of indoor unit information This step should be performed on ACCS program The w...

Страница 29: ...wing LG ACCS Login screen is displayed Enter the ID and the password and then click Login button Set the ID to admin and the password to digital21 for the first access to the Web PDI 3 When the login is successfully done the following access procedure will be executed Click 1 Click and input ID and password ...

Страница 30: ... PDI 2 24 2 Installing Web PDI 4 When the login is successfully done the initial screen of the LG ACCS is displayed as shown below Click Setting button then the system setup screen will be displayed Click ...

Страница 31: ...X RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1...

Страница 32: ...TEP 2 Click Default button then outdoor unit information group number will be generated automatically STEP 3 Erase unnecessary units by click button In this example we have 2 outdoor units Click Default button to enter the default values ...

Страница 33: ...t value as it is with no setting Type Select the module type of the outdoor unit UAC Unified air conditioner it means the outdoor unit for the unitified air conditioner Model Enter the model name of the outdoor unit Maximum consumed Set the maximum wattage for the outdoor unit to consume power W STEP 4 Fill in the Outdoor Unit Setting window For users Ø information refer to the table below After t...

Страница 34: ...hen outdoor unit information group number will be generated automatically STEP 6 Erase unnecessary units by click button In this example we have 3 indoor units for each outdoor unit If users click the button Default above information will be generated automatically ...

Страница 35: ...ion Group name Enter the air conditioner group name for the user to easily recognize Enter the indoor unit type Indoor types to set are as follows UAC Unified air conditioner SGL Single type air conditioner Type Air conditioner name Enter the air conditioner name for the user to easily recognize Caution Set to UAC type The indoor unit type should be set to UAC unified air conditioner type At prese...

Страница 36: ...overlapped within the same indoor unit number and should be set within the range of 0 15 If the user directly enters the physical address it can be easily entered incorrectly So Default value button should be used to enter Model name Enter the model name of the indoor unit Maximum consumed power Enter the maximum consumed power for the indoor unit to use The maximum consumed power depends on the m...

Страница 37: ...al Group Consumption Total consumption shows the total amount of power consumed by the air conditioners connected with PDI Group consumption shows the total amount of power consumed by the selected group 1 Groups If users choose a group the power consumption of each indoor unit belonging that group will be shown 2 1 3 2 Monitoring power consumption ...

Страница 38: ... with the Excel format It displays the wattage by indoor unit list The information for each item is as follows It shows the list of groups configured at the system Details Click button to display the detailed history of each air conditioner Air Indoor unit name of air conditioner conditioner Current Wattage of current indoor unit wattage W Total wattage Accumulated wattage of indoor unit of the ai...

Страница 39: ...the accumulated wattage of each air conditioiner the daily wattage within the query period can be queried at the detailed history of each air conditioner Setting the wattage query period You can set the period to query the wattage at the right side of the Wattage screen 3 It displays the set query period Start calendar The start date of the query period can be set at Start calendar ...

Страница 40: ... end date of the query period can be set at End calendar When you click Apply button after setting the query period the wattage within the set query period is displayed at Wattage screen When you click Cancel button all settings up to now are cancelled and it returns to the previous screen ...

Страница 41: ...enu of the LG ACCS Caution Setting the system Setting menu is used for installing the product Because the product should be installed by the professional engineer with knowledge about the air conditioner the user should not operate this menu at random The setting information is recommended to be same with the information in the central controller system such as BNU LW BACnet In order to register d...

Страница 42: ... entered At this time the group number is automatically entered so be careful The existing group may be modified by the same method Click the group to modify and when the related column is changed to yellow modify the group name In order to delete the group click the group name to delete and when the related column is changed to yellow delete the group name Group Default input button When you clic...

Страница 43: ...rst in order to add a new indoor unit or ventilator click the related input column When it is changed to the yellow input window enter the information of each item Modifying the existing indoor unit is same Click the information field of the indoor unit to modify and when it is changed to the yellow input window modify the existing information In order to delete the existing indoor unit informatio...

Страница 44: ...door unit information The third number is the indoor unit or ventilator number which can not be set overlapped within the same outdoor unit number and should be set within the range of 0 15 Model name Enter the model name of the indoor unit or ventilator Maximum Enter the maximum consumed power for the indoor unit or ventilator to consumed power use The maximum consumed power depends on the model ...

Страница 45: ...t button located at the right side of the screen the outdoor unit information input window is displayed First in order to add a new outdoor unit click the related input column When the input window is changed to yellow enter information of each item Modifying the existing indoor unit or ventilator is same Click the information column of the indoor unit or ventilator to modify and when the input wi...

Страница 46: ...r to consumed power use The maximum consumed power depends on the model Item Description Caution Deleting the outdoor unit When the outdoor unit information is deleted the information of the indoor unit connected the related outdoor unit is also deleted Note Physical and Logical group Each outdoor unit information is used as the information of physical group connecting the indoor unit However the ...

Страница 47: ...en you click Administrator information at the right side of the screen the IP PW input window is displayed Enter the ID for the user to access at the ID field and set the user s password at the PW field and then click Save button to save the setting information of the ID and the password Click Cancel button to cancel without saving the setting value The A S button is not used at present It will be...

Страница 48: ...7 Click Reset button to reload the already saved information When you click Reset button the window for confirming to execute the command is displayed and when users click OK button all information set up to now is cancelled and it returns to the previously saved state Reset button Caution Deleting the indoor unit information When you click Confirm button at the confirmation window the not saved i...

Страница 49: ...splayed Click OK button to confirm the command Click Cancel button to cancel the command and return to the previous state When you click OK button all information set up to now is saved and the saving process is informed to the user by the confirmation window Click Save button to change the information Save button ...

Страница 50: ...request the source code to the EE electronics via the following e mail you can receive the CD ROM containing it by paying the cost including media cost and transportation cost This proposal is valid for three years after receiving this product from the EE electronics The source of the GPL LGPL license can be downloaded at http www systemaircon com Some of softwares used at this product conform to ...

Страница 51: ...es of which four lines No 1 and 2 for receiving Rx and No 3 and 6 for transmitting Tx are actually used for the data transmission at the general LAN environment It can be largely classified two types according to the method for connecting the line for receiving and transmitting Direct cable It is also called the 1 1 straight cable used for connecting the other equipment at the network Cross cable ...

Страница 52: ...P No MFL37115843 After reading this manual keep it in a place easily accessible to the user for future reference Printed in Korea ...

Отзывы: