7-14
TEST AND CHECKOUT PRECEDURES AND TROUBLESHOOTING
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE OUTER CASE
FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH VOLTAGE CAPACITOR
AND REMOVING THE LEAD WIRES FROM THE PRIMARY WINDING OF THE HIGH VOLTAGE TRANSFORMER.
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER OF
WATER IN CONTAINER)IN THE OVEN.
A. TEST PROCEDURES
TRANSFORMER
MAGNETRON
1. Remove wire leads.
2. Measure resistance. (ohm meter scale: Rx1)
• Primary winding
• Secondary winding
• Filament winding
3. Measure resistance. (ohm meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Remove wire leads. Install the magnetron seal in
the correct position. Check that the seal is in
good condition.
2. Measure resistance. (ohm meter scale: Rx1)
• Filament terminal
3. Measure resistance. (ohm meter scale: Rx1000)
• Filament to chassis
Normal: Less than 1 ohm
Abnormal: Infinite
Normal: Infinite
COMPONENTS
TEST
RESULTS
SECONDARY
WINDING
PRIMARY
WINDING
FILAMENT
WINDING
Approx. 0.2 to 0.5 ohms
Approx. 50 to 120 ohms
0 ohm
Normal: Infinite
Normal: Infinite
Filament
Antenna
Gasket
Chassis
Содержание MV1611BB
Страница 7: ...4 1 OPERATING INSTRUCTIONS CONTROL PANEL 1 2 4 7 10 13 16 3 6 5 8 12 14 17 15 9 11 ...
Страница 9: ...5 1 OVERALL CIRCUIT DIAGRAM SCHEMATIC DIAGRAM DIODE 5 PTC RV U ...
Страница 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD KEY MATRIX ...
Страница 34: ...7 23 PROBLEM F No buzzing when touching the key between stages or at end of cooking 1 ...
Страница 35: ...7 24 PROBLEM Ventilation fan does not operate when ON OFF key is touched 1 Check 1 POWER SUPPLY 2 FUSE ...
Страница 37: ...1005 1000 1002 1004 1006 1007 1008 1003 W102 1009 8 2 DOOR PARTS I EV FOR MODEL ...
Страница 38: ... 8 4 CONTROLLER PARTS I 2004 2002 2000 MBM2 TECHNICAL CARD 2008 2006 W106 W101 EV FOR MODEL ...
Страница 40: ... 8 7 LATCH BOARD PARTS 4001 W102 4000 4002 4003 4002 4004 EV ...
Страница 44: ......