LG Multi V ARNU093TUD4 Скачать руководство пользователя страница 1

http://www.lghvac.com

www.lg.com

Copyright © 2014 - 2018 LG Electronics Inc. All Rights Reserved.

INSTALLATION MANUAL

AIR

CONDITIONER

Ceiling Cassette - 1Way

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring 
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thor-
oughly.

P/NO : MFL68686505
Rev.03_040318

ENGLISH

FRANÇAIS

ESP
AÑOL

Содержание Multi V ARNU093TUD4

Страница 1: ...e 1Way Please read this installation manual completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thor oughly P NO MFL68686505 Rev 03_040318 ENGLISH FRANÇAIS ESPAÑOL ...

Страница 2: ...e hazard When transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your finger When installing in a wall Make sure the wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal ...

Страница 3: ...on 9 Wiring Connection 10 Flaring work 11 Installation of Decoration Panel Panel Type 12 Installation of Decoration Panel Grille Type 13 Plumbing materials and storage methods 14 Drain Piping 15 DIP Switch Setting 16 Group Control Setting 20 Model Designation 20 Airborne Noise Emission 20 Limiting concentration TABLE OF CONTENTS Table of contents ENGLISH ...

Страница 4: ...ty Shape Paper pattern for installation 1 EA Installation and Owner s manual 1 EA Name Quantity Shape Clamp metal 2 EA Insulation for fitting Conduit mounting plate 1 SET 1 EA Drain hose 1 EA Plastic band 8 EA Washer for hanging backet 4 EA for gas pipe for liquid pipe Panel type Grille type Screws for fixing panels are attached to decoration panel Installation Tool ...

Страница 5: ... electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wi...

Страница 6: ...jury fire or explosion Do not turn on the breaker or power under condition that front panel cabinet top cover control box cover are removed or opened Otherwise it may cause fire electric shock explosion or death Operación Do not store or use flammable gas or combustibles near the product There is risk of fire or failure of product Installation Always check for gas refrigerant leakage after install...

Страница 7: ...t is installed near the sea the installation parts may be corroded by salt The installation parts and the unit should be taken appropriate anti corro sion measures Avoid the following installation location 1 Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated These may cause heat exchange efficiency reduction or water drops drain pump mal function I...

Страница 8: ...lect and mark the position for fixing bolts and piping hole Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose Drill the hole for anchor bolt on the wall Set screw of paper model 4 pieces Paper model for installation Ceiling board 70 mm 2 3 4 inch Adjust the same height Ceiling board Ceiling Flat washer for M10 accessory Keep t...

Страница 9: ...ng in the casing of electrical fittings are liable to come loose from vi brations to which the unit is subjected during the course of transportation Check them and make sure that they are all tightly fastened If they are loose it could give rise to burn out of the wires 4 Confirm the Specification of power source 5 Confirm that electrical capacity is sufficient 6 Be sure that the starting voltage ...

Страница 10: ...ing tool When none are available follow the instructions below Do not connect wiring of different thicknesses to the power terminal block Slack in the power wiring may cause abnormal heat When connecting wiring which is the same thickness do as shown in the figure below u Precautions when laying power and ground wiring Round pressure terminal Power wire Ground wire Use round pressure terminals for...

Страница 11: ...nd side covers Air conditioner unit Decorative panel Side cover Decorative panel fixing screws hexagon M6 screws tightening about 20 mm 25 32 inch Air inlet panel Air outlet vane Plasma filter applied only to plasma model Mesh Control box cover The decoration panel has its installation direction Before installing the decoration panel always remove the paper template Cool air leakage no good Decora...

Страница 12: ...ide covers Air conditioner unit Decorative panel Plasma filter applied only to plasma model Mesh Control box cover Decorative panel fixing screws hexagon M6 screws tightening about 20 mm 25 32 inch Side cover Air inlet grille Air outlet vane The decoration panel has its installation direction Before installing the decoration panel always remove the paper template Cool air leakage no good Decorativ...

Страница 13: ... cutting pipe pipe entrance should be taken down Pipe entrance should be fitted cap when pass through the walls No dust in the pipe Until the connection is completed the plumbing pipe entrance should be strictly controlled Pipe entrance should be taken side or bottom When removal burr after cutting pipe pipe entrance should be taken down Pipe entrance should be fitted cap when pass through the wal...

Страница 14: ...ort Upward routing not allowed Pipe clamp Indoor unit 1 50 1 100 Max 700mm 27 9 16 inch Feed water Drain pump Drain pan Flexible drain hose accessory Main drain pipe Glue the joint Drain port Drain hose connection Use the clip accessory 1 50 1 100 slope Hanger distance Hanger bracket Max 700mm 27 9 16 inch Flexible drain hose Insulation Metal clamp Max 300 mm 11 13 16 inch 1 15 m 3 3 49 2 ft Drain...

Страница 15: ...ide Vane Selection tropical region Spare Master Wired Wireless remote controller Selection of Manual or Auto operation Mode Continuous operation Removall Linkage Removal Up side Down side Vane General model Slave Auto Working Up side Vane Only Tropical model Off Off Off Off Off Off Off Off 2 Outdoor Unit 1 Indoor Unit In case that the products meet specific conditions Auto addressing function can ...

Страница 16: ...ual of the wireless remote controller n DIP Switch in PCB Master Setting No 3 Off Slave Setting No 3 On Indoor Unit DIP Switch GND Signal 12V Master Slave Slave Slave Display Error Message Only connect serial signal and GND lines between indoor units or LGAP Network System Master 16 Indoor Unit Installation If you want to use the two setpoint function you should be installed the both new thermosta...

Страница 17: ...e to control 16 indoor units Max with the master wired remote control h Other than those it is same with the Group Control 1 2 Group Control 2 n Wired remote controllers Standard Indoor Units 1 It is possible to 16 indoor units Max by one wired remote controller Set only one indoor unit to Master set the others to Slave 2 It is possible to connect with every type of indoor units 3 It is possible t...

Страница 18: ...AU Standard Standard FAU FAU Fresh Air Intake Unit Standard Standard Indoor Unit h In case of connecting with standard indoor unit and Fresh Air Intake Unit separate Fresh Air Intake Unit with standard units N M 16 Because setting temperature are different h Other than those it is same with Group Control 1 3 Group Control 3 n Mixture connection with indoor units and Fresh Air Intake Unit ...

Страница 19: ...ble to connect two remote controller 3 It is possible to use wireless remote controller at the same time 4 It is possible to connect with Dry Contact and Central controller at the same time 5 In case that any error occurs at indoor unit the error code is displayed on the wired remote controller 6 There isnʼt limits of indoor unit function Indoor unit 2 EA Wired remote controller Indoor unit 1 EA W...

Страница 20: ...ere is a cor relation between the emission and exposure levels this cannot be used reliably to determine whether or not further precautions are required Factor that influence the actual level of exposure of the work force include the characteristics of the work room and the other sources of noise i e the number of equipment and other adjacent processes and the length of time for which an operator ...

Отзывы: