A. OUTER CASE REMOVAL
1) Disconnect the power supply cord from the outlet.
2) Remove the screws from the rear and along side
edges of the case.
The outer case must be moved backward to be lifted
off.
B. POWER SUPPLY CORD
1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of
the earth terminal.
CAUTION: DISCHARGE THE HIGH VOLTAGE
CAPACITOR BEFORE SERVICING
(refer to page 2-1)
C. CONTROL PANEL ASSEMBLY
1) Disconnect the leadwire from the PCB SUB ASS’Y
2) Remove the screws for the earth and securing the
control panel.
3) Lift control panel ASS’Y from the oven by the tab
unhooked.
5-3
MEASUREMENT OF MICROWAVE POWER OUTPUT
DISASSEMBLY AND ADJUSTMENT
• Microwave power output measurement is made with
the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000±5) g of potable water.
• The water is contained in a cylindrical borosilicate glass
vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190mm.
• The oven and the empty vessel are at ambient
temperature prior to the start of the test.
• The initial temperature (T1) of the water is (10±2)°C It
is measured immediately before the water is added to
the vessel. After addition of the water to the vessel,
the load is immediately placed on the center of the
turntable which is in the lowest position and the
microwave power switched on.
• The time T for the temperature of the water to rise by a
value
∆
T of (10±2)°K is measured, where T is the time
in seconds and
∆
T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.
• The microwave power output P in watts is calculated
from the following formula :
is measured while the microwave generator is
operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)
• The water is stirred to equalize temperature throughout
the vessel, prior to measuring the final water
temperature.
• Stirring devices and measuring instruments are
selected in order to minimize addition or removal of
heat.
WATER LOAD
TURNTABLE
P =
• T
2
: Temperature after heating
• T
0
: Temperature after bown
• M: Weight of bowl
4187 x (
∆
T) + 0.55 X (T
2
- T
0
) X M
T
Содержание MS-2682B
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 28: ...6 2 13581A 14970A 13806A 14026A 13552A 13213A 14890A 13720D 13536A 15006A DOOR PARTS ...
Страница 29: ...6 3 WTP015 23572A 23806C 23790D 250201 24781M 268711 249402 CONTROL PANEL PARTS ...
Страница 30: ...6 4 33112U WTT021 36549S WTP013 33052A 33390G 35889A 34370T WTT020 OVEN CAVITY PARTS ...
Страница 31: ...6 5 43501A 43500A 466001 WSZ085 466003 466001 44510A LATCH BOARD PARTS ...
Страница 33: ...6 7 56170D 63302A 63303A WTT021 WSZ002 647781 BASE PLATE PARTS ...
Страница 34: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 35: ...8 2 PRINTED CIRCUIT BOARD ...