5-11
COMPONENTS
TEST PROCEDURE
RESULTS
Measure the resistance.
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
A
B
C
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Normal:
Abnormal:
∞
or several
Ω
Normal: Approx. 100~200
Ω
Abnormal:
∞
or several
Ω
A ~ B
A ~ C
40 ~ 60
Ω
300~500
Ω
Содержание MS-197W
Страница 9: ...SCHEMATIC DIAGRAM 4 3 6 ...
Страница 29: ...6 2 13581A 14970A 14026A 13552A 13213A 14890A 13720D 13536A DOOR PARTS EV ...
Страница 30: ...6 3 268711 24781S 23790D 23572A 250202 249402 250201 249401 250203 WTP004 CONTROL PANEL PARTS EV ...
Страница 31: ...6 4 OVEN CAVITY PARTS 33112U WTT021 WTT010 33390G 35889A WTP013 36549S 33052A EV ...
Страница 32: ...6 5 43500A 466001 WSZ085 466003 466001 44510A LATCH BOARD PARTS EV ...
Страница 34: ...6 7 BASE PLATE PARTS 56170D 63303A WSZ002 WTT021 65006B 63302A EV ...
Страница 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 36: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 37: ......