5-14
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
Continuity.
Malfunction of
secondary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Check continuity
of secondary
switch (with
door opened).
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all, display window does not display any figures,
and no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8
Содержание MS-119
Страница 28: ...6 2 13213A 13552A 13536A 14026A 14970A 13581A 15006A 14890A 13720D DOOR PARTS EV ...
Страница 31: ...43501A 43500A 466001 WSZ085 466003 466001 6 5 LATCH BOARD PARTS EV ...
Страница 33: ...63303L 63302L 647781 WTT028 63303R 63302R 368771 WTT021 WSZ002 948503 56170D 6 7 BASE PLATE PARTS EV ...
Страница 34: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 35: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 36: ......