Страница 1: ...CROWAVE OVEN SERVICE MANUAL MODEL MS 114YF MS 114YB CAUTION BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL P NO 3828W5S1802 March 2001 Printed in Korea Website http biz lgservice com ...

Страница 2: ...tron or other microwave source and make repairs as necessary 1 interlock operation 2 proper door closing 3 seal and sealing surfaces arcing wear and other damage 4 damage to or loosening of hinges and latches 5 evidence of dropping or abuse C Before turning on microwave power for any service test or inspection within the microwave generating compartments check the magnetron wave guide or transmiss...

Страница 3: ... CIRCUIT DESCRIPTION 4 4 SERVICE INFORMATION 5 1 TOOLS AND MEASURING INSTRUMENTS 5 1 MICROWAVE LEAKAGE TEST 5 1 MEASUREMENT OF MICROWAVE POWER OUTPUT 5 3 DISASSEMBLY AND ADJUSTMENT 5 3 INTERLOCK CONTINUITY TEST 5 7 COMPONENT TEST PROCEDURE 5 8 TROUBLE SHOOTING 5 11 EXPLODED VIEW 6 1 REPLACEMENT PARTS LIST 7 1 SCHEMATIC DIAGRAM OF P C B 8 1 PRINTED CIRCUIT BOARD 8 2 P C B PARTS LIST 9 1 CONTENTS ...

Страница 4: ...ase 3 wire grounded 1 150 Watts full microwave power IEC60705 2 450 MHz 2M246 2M248J 0 99 min 99 sec 530 W x 315 H x 394 D 348 W x 242 H x 373 D 15 kg approx 17 kg approx Touch Control System Clock 1 00 12 59 Microwave Power for Variable Cooking Power level HIGH Full power throughout the cooking time 9 Saute approx 90 of Full power 8 Reheat approx 80 7 Med High approx 70 6 Medium approx 60 5 Med L...

Страница 5: ... operation of the microwave oven requires that the magnetron be assembled to the waveguide and cavity Never operate the magnetron unless it is properly installed Be sure that the magnetron gasket is properly installed around the dome of the tube whenever installing the magnetron 2 1 CAUTIONS Unlike other appliances the microwave oven is high voltage and high current equipment Though it is free fro...

Страница 6: ...ical parts of the unit Do not install the oven next to a conventional surface unit or above a conventional wall oven 5 Use microwave oven in an ambient temperature less than 104 F 40 C 6 Place the microwave oven on a sturdy and flat surface at least 10 cm 4 inches from the wall 7 Place the microwave oven as far away as possible from TV RADIO COMPUTER etc to prevent interference GROUNDING INSTRUCTI...

Страница 7: ...feature allows oven to begin functioning 9 AUTO REHEAT This menu has been preprogrammed to reheat food automatically by selecting menu 10 AUTO DEFROST This feature provides you with the best defrosting method for frozen foods 11 MICRO This feature is used for manual cooking or 2 stage cooking 12 OPTION You can select sound ON OFF demo ON OFF and scroll speed 13 POWER You can select the desired pow...

Страница 8: ...O SET CHILD LOCK Touch the pad Touch and hold PARAR BORRAR pad BLOQUEADO appear on the display TO CANCEL CHILD LOCK Touch the pad Touch and hold PARAR BORRAR pad DESBLOQUEADO disappears 9 OPTION You can select ON OFF of beeper ON OFF of demo and scroll speed To select sound ON OFF To select scroll speed To select demo ON OFF PARAR BORRAR FRIJOLES PARAR BORRAR 30 MÁS PARAR BORRAR 1ST STAGE INICIO P...

Страница 9: ...AMP MONITOR SWITCH TURN TABLE MOTOR FAN MOTOR IMPORTANT SAFETY NOTE THE SHADED AREAS ON THIS SCHEMATIC DIAGRAM INCORPORATE SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM MICROWAVE RADIATION FIRE ELECTRICAL SHOCK AND HAZARDS WHEN SERVICING IT IS ESSENTIAL THAT ONLY MANUFACTURER S SPECIFIED PARTS BE USED FOR THE CRITICAL COMPONENTS IN THE SHADED AREAS OF THE SCHEMATIC DIAGRAM NOTICE SINCE THIS IS BA...

Страница 10: ...roximately 2100 volts AC is generated in the secondary of the high voltage transformer which is increased by the action of the high voltage diode and charging of the high voltage capacitor The negative 4 000 Volts DC is applied to the filament of the magnetron WHEN THE OVEN IS SET AT ANY LEVEL EXCEPT MAXIMUM The micom controller controls the ON OFF time of relay 2 by the applied signal to vary the...

Страница 11: ...hich is graduated to 600 cc and place the beaker on the center of the turntable Set the energy leakage monitor to 2 450 MHz and use it following the manufacturer s recommended test procedure to assure correct result When measuring the leakage always use the 2 inch 5cm spacer supplied with the probe Operate the oven at its maximum output Measure the microwave radiation using and electromagnetic rad...

Страница 12: ...e test probe must be removed no faster than 1 inch sec 2 5 cm sec along the shaded area otherwise a false reading may result The test probe must be held with the grip portion of the handle A false reading may result if the operator s hand is between the handle and the probe When testing near a corner of the door keep the probe perpendicular to the surface making sure the probe horizontally along t...

Страница 13: ...s 5 K The microwave power output P in watts is calculated from the following formula 4187 x T T is measured while the microwave generator is operating at full power Magnetron filament heat up time is not included about 3 sec The water is stirred to equalize temperature throughout the vessel prior to measuring the final water temperature Stirring devices and measuring instruments are selected in or...

Страница 14: ...or be sure to check that the primary switch monitor switch and secondary switch operate normally 2 After replacing the door check for microwave energy leakage with a survey meter Microwave energy must be below the limit of 4 mW cm2 with a 275 ml water load 3 When mounting the door assembly to the oven assembly be sure to adjust the door assembly parallel to the chassis Also adjust so the door has ...

Страница 15: ... to the magnetron To prevent microwave leakage tighten the mounting screws properly making sure there is no gap between the waveguide and the magnetron G REMOVING THE TURNTABLE MOTOR 1 Remove the turntable and rotating ring 2 Lay the unit down on its back 3 Remove the turntable motor cover The turntable base cover is easily removed by pinching the eight parts with a wire cutting 4 Disconnect the l...

Страница 16: ...K INTERLOCK SYSTEM 1 INTERLOCK MECHANISM The door lock mechanism is a device which has been specially designed to eliminate completely microwave activity when the door is opened during cooking and thus to prevent the danger resulting from the microwave leakage 2 MOUNTING OF THE PRIMARY MONITOR SECONDARY SWITCHES TO THE LATCH BOARD 3 INSTALLATION AND ADJUSTMENT OF THE LATCH BOARD TO THE OVEN ASSEMB...

Страница 17: ...losed meter should indicate an closed circuit When the secondary switch operation is abnormal make the necessary adjustment or replace the switch only with the same type of switch C MONITOR SWITCH TEST Disconnect the wire lead from the monitor switch Connect the ohmmeter leads to the common COM and normally closed NC terminals of the switch The meter should indicate closed circuit in the door open...

Страница 18: ... PROCEDURE RESULTS HIGH VOLTAGE TRANSFORMER Wire leads removed MAGNETRON Wire leads removed 1 Measure the resistance Ohm meter scale Rx1 and Rx100 Primary winding Secondary winding Filament winding 2 Measure the resistance Ohm meter scale Rx1000 Primary winding to ground Filament winding to ground 1 Measure the resistance Ohm meter scale Rx1 Filament terminal 2 Measure the resistance Ohm meter sca...

Страница 19: ... Terminal to case Measure the continuity Forward Ohm meter scale Rx10000 Measure the continuity Reverse Ohm meter scale Rx10000 Normal Momentarily indicates several ohms and then gradually returns to infinite Normal Infinite Normal Continuity Abnormal Infinite Normal Infinite Abnormal Continuity NOTE When testing the magnetron be sure to install the magnetron gasket in the correct position and be ...

Страница 20: ...ec 2 6 sec 16 sec 3 8 sec 14 sec 4 10 sec 12 sec 5 12 sec 10 sec 6 14 sec 8 sec 7 16 sec 6 sec 8 18 sec 4 sec 9 20 sec 2 sec 10 22 sec 0 sec Normal A Approx 85 100 ohm B Approx 10 25 ohm Abnormal Infinite or several ohm Normal Approx 100 150 ohm Abnormal Infinite or several ohm NOTE A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON MAKE SURE THE WIRE LEADS ...

Страница 21: ...s panel to discharge any static charge built up in your body Micom model only CONDITION Microwave oven does not work Inserting many plugs into one outlet and using them at the same time blown fuse or breaker Microwave oven plug is not inserted tightly Output power is too low Low AC input voltage Food temperature is too low Using metallic ware and allowing it to touch the oven wall Sparks occur Inc...

Страница 22: ... does not turn on after setting cooking cycle 11 Display time of day does not reappear when cooking is finished 5 12 TROUBLE 1 The following visual conditions indicate a probable defective control circuit CONDITION CHECK RESULT CAUSE REMEDY 1 No input can be programmed Continuity No continuity Defective PCB assembly Loose connection Replace PCB assembly Connect them tightly Check the conn ection b...

Страница 23: ...of primary switch with door opened Disconnect one side of the wire lead connected from transformer to the high voltage capacitor and operate the unit Replace fuse Continuity Malfunction of secondary switch Replace fuse primary monitor secondary switches and RELAY RY2 of P C B Assembly No continuity Check continuity of secondary switch with door opened 2 Fuse does not blow No continuity Continuity ...

Страница 24: ...ws all figures set but oven does not start cooking while desired program times are set and START pad is touched TROUBLE 4 Oven seems to be operating but little heat is produced in oven load NOTE Simple test of power output conducted by heating one liter water for one min if available Minimum 8 5 C temperature rise is normal condition CONDITION CHECK RESULT CAUSE REMEDY Output is low Lower than 90 ...

Страница 25: ... relay 2 and check continuity relay 2 Operate the unit Abnormal Defective high voltage capacitor Replace high voltage capacitor Normal Check high vol tage capacitor Abnormal Defective high voltage diode Replace high voltage diode Normal Check high vol tage diode Abnormal Defective magnetron Replace magnetron Check magnetron TROUBLE 5 No microwave oscillation even though oven lamp and fan motor run...

Страница 26: ...LATCH BOARD PARTS INTERIOR PARTS BASE PLATE PARTS OVEN CAVITY PARTS DOOR PARTS CONTROL PANEL PARTS 6 1 EXPLODED VIEW INTRODUCTION EV MODEL MS 114YF MS 114YB ...

Страница 27: ...6 2 13213A 13552A 13536A 14026A 14970A 13581A 15006A 14890A 13720D DOOR PARTS EV ...

Страница 28: ...26638A 268711 WTP028 24781M 24510L 250201 23572A 24970A 6 3 CONTROLLER PARTS First check the rating label on the back of oven and order SVC parts accoding to ECN EV ...

Страница 29: ...6 4 OVEN CAVITY PARTS 340511 33052M 948502 33112U WTT021 WTT010 33390G 35889A 34960A 36549S 948504 WTP013 EV ...

Страница 30: ...6 5 43501A WSZ085 466001 466003 466001 43500A LATCH BOARD PARTS EV ...

Страница 31: ... 6 INTERIOR PARTS 568771 56930V 34930W WSZ002 WSZ002 WTT028 WSZ002 WSZ002 WTT037 WSZ002 56851D 50CZZH WTT028 54810C WSZ002 948501 35012A WSZ002 56912B 55262A 56324A 55900A 50FZZA 54974S 55006F 56549F EV ...

Страница 32: ...6 7 BASE PLATE PARTS EV 63303L 63302L 647781 WTT028 63302R WTT021 WSZ002 948503 56170D 63303R ...

Страница 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...