5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1.Setting time does
not count down
when touching
START pad.
No continuity.
Continuity.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
connector and
P.C.B assembly.
2. Fan motor or
oven lamp
do not turn
on.
Abnormal.
Defective fan
motor.
Replace fan
motor.
Check fan motor.
Abnormal.
Defective oven
lamp.
Replace oven
lamp.
Check oven lamp.
Normal.
No continuity.
Continuity.
Defective P.C.B
assembly.
Replace P.C.B
assembly.
Loose connection.
Connection then
tightly.
Output is low.
Lower than 90% of
rating voltage.
Normal.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Disconnect the
wire leads from
relay 2 and check
on and off time
with multitester.
Abnormal.
Normal.
Abnormal.
Defective
magnetron.
Replace
magnetron.
Defective P.C.B
assembly.
Replace P.C.B
assembly.
Measure the
output power.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while
desired program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operation but little heat is produced in oven load.
NOTE: Simple test of power output-conducted by heating one liter water for one min. if available.
Содержание MH2044DB
Страница 9: ...MGT THERMAL GRILL SCHEMATIC DIAGRAM 4 3 7 5 3 1 8 BN ...
Страница 29: ...DOOR PARTS EV 13581A ...
Страница 30: ...CONTROLLER PARTS EV 24781M ...
Страница 31: ...33390B 33112U 44360A 33052M 35300A 36549S 35889A 33390G 35026G ...
Страница 32: ...LATCH BOARD PARTS 466001 466003 466001 43500A 569128 EV ...
Страница 34: ...BASE PLATE PARTS 56170D EV ...
Страница 35: ...R SERVICE PARTS 7 1 REPLACEMENT PARTS LIST ...
Страница 36: ......