A. PRIMARY INTERLOCK SWITCH TEST
When the door is closed slowly, an audible
click
should be heard at the same time or successively
at intervals. When the door is opened slowly, the
latches should activate the switches with an
audible
click
.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make
the necessary adjustment or replace the switch
only with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the switch
Door
Door
(Wire leads removed)
with a Multi-meter
open
close
Primary
Switch
Monitor
Switch
NOTE :
After checking for the continuity of switches, make sure that are
correctly connected.
COM
NO
COM
NO
NC
COM
INTERLOCK CONTINUITY TEST
Secondary
Switch
Содержание MC2841SPS
Страница 1: ...MODEL MC2841SPS ...
Страница 9: ...SCHEMATIC DIAGRAM 4 3 Conv therostat ...
Страница 31: ... 6 2 DOOR P ARTS 13581A ...
Страница 32: ... 6 3 CONTROL PANEL PARTS 268711 23572A 23506A ...
Страница 33: ... 6 4 OVEN CAVITY PARTS 33052M 36549S 33390G 34370T 35889A 33390M 33112U 372901 35300A 33390L 33390H ...
Страница 34: ... 6 5 LATCH BOARD PARTS 33052N 466001 466003 466001 43500A ...
Страница 36: ... 6 7 BASE PLATE PARTS 56170D ...
Страница 37: ......
Страница 39: ......