The cause of malfunction
Indoor TH. is short or open.
Temp. of Heat sink is over 95°C.
Comunication error (serial
comunication).
DC peak error.
Running current is
overloaded.
D-PIPE TH is short or open.
The LED01M will be blinking
twice.
The LED01M will be blinking 4
times.
The LED01M will be blinking 5
times.
The LED01M will be blinking 6
times.
The LED01M will be blinking 7
times.
The LED01M will be blinking 10
times.
Keep operating state.
Restart comp. on in the OLP short
state.
The operation is off(enable to restart
by remote controller).
Compressor will be turned off
immediately.
Compressor will be turned off
immediately.
Compressor will be turned off
immediately.
Malfunction indicator
The operating state
Error
Code
-50-
1. The malfunction indicator of indoor (see the operating LED of the INDOOR)
Self-diagnosis function
The cause of malfunction
Error
Code
1
Indoor TH. is short or open.
Outdoor TH. is short or open.
Temp. of Heat sink is over
95°C.
Comunication error (serial
comunication).
DC peak error.
Running current is
overloaded.
D-PIPE TH is short or open.
The operating LED will be
blinking once.
The operating LED will be
blinking twice.
The operating LED will be
blinking 4 times.
The operating LED will be
blinking 5 times.
The operating LED will be
blinking 6 times.
The operating LED will be
blinking 7 times.
The LED01M will be blinking 10
times.
Keep operating state.
Keep operating state.
Restart compressor when OLP TH
Temp is 85°C below.
The operation is off(enable to restart
by remote controller).
Compressor will be turned off
immediately.
Compressor will be turned off
immediately.
Compressor will be turned off
immediately.
Malfunction indicator
The operating state
2. The malfunction indicator of outdoor (see the LED01M on the outdoor PCB ass’y)
❈
Error code
➅
,
➆
can’t be operated unless the power cord is removed.
2
4
5
6
7
2
4
5
6
7
10
10
Содержание LS-J0762NM
Страница 64: ... 64 2 MAIN PCB ASS Y OUTDOOR PCB ASS Y SVC PART LIST 6871A20265A 9K_Series AC TOP VIEW BOTTOM VIEW ...
Страница 66: ...Schematic Diagram 66 Indoor _YL _UL Series ...
Страница 67: ... 67 Indoor _NM _NN Series ...
Страница 68: ... 68 Outdoor 7K AC Series ...
Страница 69: ... 69 Outdoor 12K AC Series ...
Страница 70: ... 70 Outdoor 9K DC Series ...
Страница 73: ... 73 Outdoor 12K DC Series ...
Страница 80: ...Memo 80 ...
Страница 81: ... 81 Memo ...
Страница 82: ...P No 3828A20061S February 2003 Printed in Korea ...