-14-
4. Cooling mode operation
• Operating frequency of compressor depend on the difference of the temperature.
(= intake air Temp.- Compressor off Temp.
• Compressor off temp.= setting temp. -0.5°C
on temp. = setting temp. +0.5°C
• If compressor operates at some operating frequency, the operating frequency of compressor cannot be
changed within 30 seconds.
• Condition of compressor turned off
- When intake air temperature stay at the temperature between setting temp. -0.5°C and setting temp.
-1.0°C for 3 minutes continuously.
- When intake air temperature reaches below the temperature of setting temp. -1.0°C.
• Compressor 2 minutes delay
- The compressor can restart minimum 2 minutes later after compressor off.
Temp. differences
Comp. Operating frequency
over 3.0°C
Step 7
over 2.5°C
Step 6
2.0~2.49°C
Step 5
1.5~1.99°C
Step 4
1.0~1.49°C
Step 3
0.5~0.99°C
Step 2
0.0~0.49°C
Step 1
[The operating freq. step of comp.]
[The targeting operating freq. of comp. each model]
Model
7K Series(AC)
35
41
45
56
64
68
78
9K Series(AC)
35
48
62
72
83
90
99
12K Series(AC)
30
40
45
55
61
67
72
9K Series(DC)
15
22
32
40
51
54
58
12K Series(DC)
15
28
40
53
66
71
76
Comp. Operating frequency
Step 1
Step 2
Step 3
Step 4
Step 5(Fc)
Step 6
Step 7
Содержание LS-J0762NM
Страница 64: ... 64 2 MAIN PCB ASS Y OUTDOOR PCB ASS Y SVC PART LIST 6871A20265A 9K_Series AC TOP VIEW BOTTOM VIEW ...
Страница 66: ...Schematic Diagram 66 Indoor _YL _UL Series ...
Страница 67: ... 67 Indoor _NM _NN Series ...
Страница 68: ... 68 Outdoor 7K AC Series ...
Страница 69: ... 69 Outdoor 12K AC Series ...
Страница 70: ... 70 Outdoor 9K DC Series ...
Страница 73: ... 73 Outdoor 12K DC Series ...
Страница 80: ...Memo 80 ...
Страница 81: ... 81 Memo ...
Страница 82: ...P No 3828A20061S February 2003 Printed in Korea ...